CV-A20
CL / CV-A80
CL
(V W idth )L
36L
DV AL
FVAL
LVAL
DAT A OUT
1L:
1 LVAL Period
1L:
1100ck(14.815uS)
1ck:74.25MHz
V W
id
th
1 FVAL P eriod
45L+(V W idth)L
ST ROB E OUT
45L
9L
V S
ta
rt
Fig.22. Vertical timing, Window scan
LVAL
EXT TRIG
The following equation is used for calculating the minimum trigger interval.
(Strobe delay 0 + Strobe Delay Time) + Strobe out (0 to1L) + 38L + 9L(OB) + Effective
2L + 1L
Whereby, Strobe delay 0 is inherent delay which is fixed at 35 clk ± 1ck,
Strobe delay time is determined by Strobe Enable Delay Time
Strobe out period is determined by Readout Begin Period
38L + (0 to 1L) + 9L(OB) and 2L+1L are fixed values.
Effective period may vary depending on scanning format.
6.4.3.
Widowing Timing Chart
The following drawings show vertical and horizontal timing for Windowing mode on continuous
operation.
FVAL Period
(Continuous, Windowing)
*
A
Full scan
1 L
Window scan
1 L
DATA OUT
STROBE OUT
FVAL
DVAL
* A
Trigger Unacceptable Period
Fig.21. Minimum Trigger period
17