8.5.2 Edge Pre-select Trigger Mode
An external trigger pulse initiates the capture, and the exposure time (accumulation time) is
defined by preset, programmable or Exposure Time Abs register.
The resulting video signal will start to be read out after the selected shutter time.
For timing details, refer to fig. 17 through fig. 24.
To use this mode:
Set function:
Trigger mode
Edge pre-select
Scanning
Full, Partial
V Binning
ON / OFF
Shutter mode
Edge pre-select, programmable,
Exposure Time Abs
Input:
Ext. trigger.
12-pin Hirose GPIO
Important notes on using this mode
1.
The minimum trigger interval >2 LVAL.
2.
Depending on the timing of the leading edge of the trigger pulse in relationship to
FVAL, accumulation will be synchronous or asynchronous in relationship to LVAL. See
8.3.4 Auto-detect LVAL-sync / async accumulation.
3. The minimum trigger interval is as follows.
Scan mode
Minimum interval
[
L
]
Normal Full
513
2/3 Partial
359
1/2 Partial
287
1/4 Partial
179
1/8 Partial
125
Vertical binning
259
Note: In order to keep the minimum trigger interval in the partial scan mode, the
exposure time should not exceed the line number at normal scan. If the exposure time
is set longer than that, the trigger interval is longer by (Exposure time – normal scan
line number). The maximum exposure time is 511L.