CM-030GE-RH
52
0xA610
Event Selector
Acquisition Trigger
GevEventtreigger
RW
4
Selector Value
0
Event message ON/OFF
0
Exposure Start
GevEventStartOfExposure
1
0
Exposure End
GevEventEndOfExposure
2
0
Frame Transfer Start
GevEventStartOfTransfer
3
0
Frame Transfer End
GevEventEndOfTransfer
4
0
Event Notification
EventNotification
0=Disable
1=Enable
User Sets
Address
Display Name
(JAI Control Tool)
GenICam name
Read /
Write
Size Value / Range of value
Description
Default
value
0xA300
UserSet Save
UserSetSave
W
4
1=User area1
Allows use to save all
camera settings. Last used
area number becomes new
default.
1
0xA304
UserSet Load
UserSetLoad
W
4
0=Factory area
1=User area1
Allow the user to recall all
camera settings.
0
0xA308
UserSet Selector
UserSetSelector
RW
4
Whenreceiving
following
commands,store the
parameters
0xA300
0xA304
Check the used data,
0=Factory or1=User
0