CM-030GE-RH
16
Start Point
End Point
Length
Start Point
End Point
Length
Line Source
Line Polarity
6.4.2 12-bit counter
Address
Internal Name
GenIcam Name Access Size
Value (Range)
0xB000
Counter Clock Choice
ClockSource
R/W
4
0x00: 25MHz
0x01: Pixel Clock
0xB004
Counter Dividing Value
ClockPreScaler
R/W
4
0x000: Bypass
0x001: 1/2 Dividing
0x002: 1/3 Dividing
|
0xFFF: 1/4096 Dividing
6.4.3 Pulse generators (20-bit x 4)
There are 4 pulse generators (designated 0 through 3) that can be used to create various
timing scenarios by programming start point, endpoint, length and repeats.