CM-140GE / -RA/-UV / CB-140GE / -RA
- 50 -
In the case of Sequential EPS, (Trigger source is Software)
For each sequence,
The following table shows the minimum trigger interval in asynchronous accumulation mode. In
the sequential mode, only asynchronous mode is functional. Therefore, the trigger timing should
be set so that the timing is not in synchronous mode.
Full Scan
1/2 Partial
2/3 Partial
1/4 Partial
1/8 Partial
1/2 V Binning
1055 L
821 L
705 L
531 L
445 L
530 L
The conditions for this table are that shutter speed should be set the same for all sequences. If
the shutter speed is different, the difference of exposure time should be added. It is
recommended to set the exposure time in order of the shortest to the longest one.
Do not input the trigger just after the sequence is reset. It requires at least 500ms delay.
In sequential mode, the exposure should be adjusted so that the LVAL async mode can always
function.