BM-500CL / BB-500CL
- 7 -
5.
Pin Assignment
5.1.
12-pin Multi-connector (DC-IN/Trigger)
Type: HR10A-10R-12PB-01 (Hirose) male.
Use the part number HR10A-10P-12S for the cable side
*1) XEEN output can be configured with complementary emitter follower circuit or open collector
by internal switch setting. The default is the complementary emitter follower circuit. See
chapter 5.3.3 for details.
*2) Factory default is trigger via Camera Link
*3) 75 ohm termination can be enabled by SW 800. See Chapter 7.1
5.2.
Digital Output Connector for Camera Link
Type: 26-pin MDR connector (3M 10226-1A10PL)
Fig.3 26-Pin Camera Link Connector
Pin No
In/Out
Name
Note
1,14
Shield
GND
2(-),15(+)
O
TxOUT0
Data out
3(-),16(+)
O
TxOUT1
4(-),17(+)
O
TxOUT2
5(-),18(+)
O
TxClk
Clock for CL
6(-),19(+)
O
TxOUT3
Data out
7(+),20(-)
I
SerTC (RxD)
LVDS Serial Control
8(-),21(+)
O
SerTFG (TxD)
9(-),22(+)
I
CC1 (Trigger)
Trigger IN
10(+),23(-)
N.C
11,24
N.C
12,25
N.C
13,26
Shield
GND
Pin no.
Signal
Remarks
1
GND
2
+12 V DC input
3
GND
4
Iris video
Only for Continuous mode. TR=0
5
GND
6
NC
7
NC
8
GND
9
XEEN out
*1)
10
Trigger in
TI=1 (or Camera Link TI=0). *2)
*3) 75 ohm termination
11
DC+12V
12
GND
Fig. 2 Hirose 12-pin connector