BM-141GE / BB-141GE
70
13.2. Specification table
Specifications
BM-141GE
BB-141GE
Scanning system
Progressive scan
Frame rate full frame
30.12 frames/sec. Progressive (1052 lines/frame)
Pixel clock
58 MHz
Line frequency
31.693 kHz (1H = 31.551 µs) (1830 pixel clock/line)
CCD sensor
2/3 inch Monochrome ICX285AL
2/3 inch Bayer Color ICX285AQ
Sensing area
8.98 (h) x 6.7 (v) mm 2/3 inch diagonal
Cell size
6.45 (h) x 6.45 (v)
m
Active pixels
1392 (h) x 1040 (v)
Pixels in video output.
Full Scan
2/3 partial Scan
1/2 partial Scan
1/4 partial Scan
1/8 partial Scan
Variable Partial Scan
Vertical Binning
Draft
Region-of-interest (ROI)
1392 (h) x 1040 (v) 30.12 fps. H = 31.693 kHz
1392(h) x 694 (v) 41.05 fps H= 31.693 kHz
1392 (h) x 520 (v) 50.06 fps. H = 31.693 kHz
1392(h) x 260 (v) 74.57 fps. H = 31.693 kHz
1392 (h) x 130 (v) 98.73 fps. H = 31.693 kHz
Start line from 1 to 1025, height(lines) from 8 to 1032
1392 (h) x 520 (v) 50.18 fps. H = 26.447kHz ( BM-141GE only))
1392 (h) x 260 (v) 101.17 fps. H = 27.128 kHz (BB-141GE only)
User Definable. Memory read-out
Note: Partial scan, Vertical Binning and Draft mode cannot be used at the same
time
Sensitivity on sensor (minimum)
0.03 Lux (Max. gain, Shutter OFF, 50%
video )
0.2 Lux (Max. gain, Shutter OFF,50%
Green, w/IR cut filter)
S/N ratio
More than 58 dB (0dB gain)
Digital Video output
GigE Vision Compliant
Mono8,Mono10,Mono10_Packed
Mono 12, Mono12_Packed
GigE Vision Compliant
BAYRG8,BAYGB8,BAYRG10,BAYGB10
BAYRG12, BAYGB12
White Balance
n/a
Manual/One push
Continuous Auto (3200K to 9000K)
Preset (3200K,4600K,5600K)
Iris video output. Analogue
0.7 V p-p , enabled by internal switch
Gain
Manual / AGC : -6 to +24 dB (1 Step 0.0358 dB)
Blemish Correction
ON / OFF
LUT (Look Up table)
OFF: γ=1.0 ON: γ=0.45, LUT ( 256 points)
Synchronization
Internal X-tal
GPIO Module
Input/output switch
Clock Generator ( One)
Pulse Generators ( Two)
Configurable 16-in / 12-out switch
12-bit counter based on Pixel clock
19-bit counter programmable for length, start point, stop point, repeat
Hardware Trigger modes
Edge Pre-Select , Pulse Width Control, RCT, Frame Delay and Sequence
Smearless mode
Available for EPS (Async)
OB area transfer mode
ON / OFF
Event message
SYNC / ASYNC mode ( Trigger mode status when exposure starts )
Exposure start, Exposure end, Trigger IN, Video start, Video end
Electronic Shutter
Preset Shutter speed
Programmable exposure
Exposure Time (Abs)
Exposure Auto continuous
GPIO plus Pulse Width
OFF(1/30) and 1/60 to 1/10,000 in 9 steps
2L(63µs) to 1052 L ( 33.19 ms) in 1L steps
µsec – user definable. Same range as PE
64L to 1052L (1/500s to 1/30s)
max. 2 sec ( Can be set by 100µs unit or Pixel Clock unit)
Содержание BB-141GE
Страница 5: ...BM 141GE BB 141GE 5 Change History 74 User s Record 75 ...
Страница 18: ...BM 141GE BB 141GE 18 Line Source 6 5 GPIO programming examples 6 5 1 Pulse generator setting sreen ...
Страница 64: ...BM 141GE BB 141GE 64 11 4 7 Feature Properties Guru ...
Страница 65: ...BM 141GE BB 141GE 65 ...
Страница 66: ...BM 141GE BB 141GE 66 ...
Страница 67: ...BM 141GE BB 141GE 67 ...