AM-1600CL / AB-1600CL
- 30 -
Exposure
Min.
Value
Max.
Value
RW
Command
Note
Common
Control Mode
Selection
-
-
RW
:R0010@0080#=0000000X
Select Exposure control mode.
0: Preset mode control、1: Line step
mode
Preset Mode
Table Type
-
-
RW
:R0010@0084#=0000000X
Select Factory or User table
on Preset mode
Max Selection for
Preset Factory
0
0xF RW
:R0010@0088#=0000000X
Maximum index( size) of Factory table
on Preset mode
Current Selection
for Preset Factory
0
0xF RW
:R0010@008C#=0000000X
The current using index of Factory
table on Preset mode
Max Selection
for Preset User
0
0xF RW
:R0010@0090#=0000000X
Maximum index( size) of User table
on Preset mode
Current Selection
for Preset User
0
0xF RW
:R0010@0094#=0000000X
The current using index of User table
on Preset mode
Direct Mode
Table Type
-
-
RW
:R0010@0098#=0000000X
Select Factory or User table on
Line Step mode
Min Direct
Exposure
Time Factory
3
3248 RW
:R0010@009C#=00000XXX
Minimum step number of Factory set
on Line Step control
Max Direct
Exposure Time
Factory
3
3248 RW
:R0010@00A0#=00000XXX
Maximum step number of Factory set
on Line Step control
Current Direct
Exposure Time
Factory
3
3248 RW
:R0010@00A4#=00000XXX
Current step number of Factory set
on Line Step control
Min Direct
Exposure
Time User
3
3248 RW
:R0010@00A8#=00000XXX
Minimum step number of User set
on Line Step control
Max Direct
Exposure
Time User
3
3248 RW
:R0010@00AC#=00000XXX
Maximum step number of User set
on Line Step control
Direct Exposure
Time User
3
3248 RW
:R0010@00B0#=00000XXX
Current step number of User set
on Line Step control
Functions
Exposure
Preset Mode
Line Step Mode
LUT
Min.
Value
Max.
Value
RW
Command
Note
-
-
RW
:R0010@00C0#=00000000
-
-
RW
:R0010@00C0#=00000001
-
-
RW
:R0010@00C0#=00000002
-
-
RW
:R0010@00C0#=00000003
-
-
RW
:R0010@00C0#=00000004
-
-
RW
:R0010@00C0#=00000005
-
-
RW
:R0010@00C0#=00000006
-
-
RW
:R0010@00C0#=00000007
-
-
RW
:R0020@0130#=0000000X
0: Linear , 1: 0.45,
2 to 7 : User 1 to User 6
Load
-
-
WO
:R0020@0134#=00000001
Write "00000001" to execute " Load ".
Save
-
-
WO
:R0020@0138#=00000001
Write "00000001" to execute " SAVE ".
Point 0
0
0 RW
:R0020@0140#=00000000
X coordinate position of LUT first point.
MUST be 0.
Point 1
0
65535 RW
:R0020@0144#=0000XXXX
X coordinate position of LUT 2nd point.
Point 2
0
65535 RW
:R0020@0148#=0000XXXX
X coordinate position of LUT 3rd point.
Point 3
0
65535 RW
:R0020@014C#=0000XXXX
X coordinate position of LUT 4ht point.
Point 4
0
65535 RW
:R0020@0150#=0000XXXX
X coordinate position of LUT 5th point.
Point 5
0
65535 RW
:R0020@0154#=0000XXXX
X coordinate position of LUT 6th point.
Point 6
0
65535 RW
:R0020@0158#=0000XXXX
X coordinate position of LUT 7th point.
Point 7
0
65535 RW
:R0020@015C#=0000XXXX
X coordinate position of LUT 8th point.
Point 8
0
65535 RW
:R0020@0160#=0000XXXX
X coordinate position of LUT 9th point.
Point 9
0
65535 RW
:R0020@0164#=0000XXXX
X coordinate position of LUT 10th point.
Point 10
0
65535 RW
:R0020@0168#=0000XXXX
X coordinate position of LUT 11th point.
Point 11
0
65535 RW
:R0020@016C#=0000XXXX
X coordinate position of LUT 12th point.
Point 12
0
65535 RW
:R0020@0170#=0000XXXX
X coordinate position of LUT 13th point.
Point 13
0
65535 RW
:R0020@0174#=0000XXXX
X coordinate position of LUT 14th point.
Point 14
0
65535 RW
:R0020@0178#=0000XXXX
X coordinate position of LUT 15th point.
Point 15
0
65535 RW
:R0020@017C#=0000XXXX
X coordinate position of LUT 16th point.
Point 16
0
65535 RW
:R0020@0180#=0000XXXX
X coordinate of 17th point. This is
the virtual point to get the last slope.
User 5
User 6
Select Table
Request Job
User Table
Generation
Functions
Table Selection
Linear
Pivot
The curve data can only be changed
on Factory
Gamma
User 1
The curve data can be changed on
User and the tool is supplied.
User 2
User 3
User 4