AM-1600CL / AB-1600CL
- 44 -
o
V-Reset
Use this area to indicate whether or not the camera will be controlled by triggering.
Free-run : Continuous operation by internal trigger
Trigger-Run : Indicates that an external trigger will be used.
Select EPS or PWC for Trigger-Run mode
p
Trigger Control
Select whether the trigger input will come via the HIROSE 12-pin or the Camera Link
connector. Also select the trigger polarity for Camera Link and 12-pin respectively.
q
Pixel Depth
Select the depth of the video output through Camera Link. Choose from 12 bits, 10 bits
or 8 bits.
r
Frames to Capture
Select the number of frames to capture per trigger: from 1 to 4 frames
s
Gamma (AM-1600CL only)
Select the type of video output response from the following choices (this function is only
for AM-1600CL).
■
Linear (
γ
=1.0)
■
Gamma (
γ
=0.45
)
■
USER 1 to 6: User programmable LUT (refer to LUT instructions below)