Fig.42 Reset Continuous Trigger
10.5.7 Sequential Trigger Mode (EPS)
This mode allows the user to define a preset sequence of up to 10 images, each with its own
ROI, Shutter and Gain values. As each trigger input is received, the image data with the
preset sequence is output as described below.
Trigger
Sequence
Operation
Fig.43 Sequential Trigger Mode
10.5.7.1 Setting parameters
Following parameters in Sequence control should be adjusted.
(1)
Sequence Mode
:
Sequence Mode = On is to set to Sequential EPS
Trigger mode.
(2)
Sequence Repetition Count
:
(applicable value
:
0
~
255)
This sets how many times the sequence is repeated.
If the last Sequence Repetition Count is completed, the sequence table is set tothe Last
Sequence setting. If further trigger pulses are input, the settings for the Last Sequence, are
repeated until Reset Sequence is input.
Sequence Repetition Count = 0 will cause the sequence to repeat indefinitely.