AD-130GE
59
10.5.4 Pulse Width Control (PWC) trigger mode
In this mode the accumulation time is equal to the trigger pulse width. Here it is possible to
have a long time exposure. The maximum recommended time is <60 frames.
In PWC mode, only LVAL asynchronous accumulation is effective.
To use this mode:
Set function:
Acqusition mode
:
Frame Start
Trigger mode
:
ON
Sync mode
:
Sync / Async
Exposure Mode
:
Trigger Width
Exposure time
:
Exposure time/Exposure time(us)/
Exposure time(Raw)
Other functions
Input:
External Trigger
Trigger Source
This function can be set by selecting Pulse width control in Exposure mode of JAI Acquisition Control.
However, Acquisition Mode,
Sync Mode,
Exposure Time, and so on should be set.
Important Note:
The minimum duration of the trigger is 2L. The minimum period of trigger is as follows.
10.5.4.1 Timing chart
Following charts are the timing if Sync mode is set to Sync.
In this case, the trigger input is the same for both camera#0 and #1 and the output timing is the
same.
SYNC Mode Smearless
Enable
Minimum Trigger interval (Line)
SYNC Mode
=SYNC
False
LVAL
ASYNC
(Trigger Pulse width: Min.2L) + Frame interval in
continuous operation(L) + 4L
True
LVAL
ASYNC
(Trigger Pulse width:Min.197L+2L) + Frame interval in
continuous operation(L) + 4L
SYNC Mode
=ASYNC
False
LVAL
ASYNC
(Trigger Pulse width: Min.2L) + Frame interval in
continuous operation (L) + 4L
True
LVAL
ASYNC
(Trigger Pulse width : Min.197L+2L) + Frame interval
in continuous operation(L) + 4L
Pulse-width trigger is available only in LVAL Async accumulation.