AD-130GE
49
3) 1 frame is output
4) AcquisitionActive becomes ―FALSE‖ (stop capturing)
Fig.31 Single frame timing
This drawing shows a case where the trigger is ―OFF‖. If the trigger is ON,
FrameActive becomes ―TRUE‖ on the different timing of AcquisitionActive.
◆
Forcing acquisition to stop
While AcquisitionActive is ―TRUE‖, if AcquisitionEnd or AcquisitionAbort is
initiated, AcquisitionActive becomes ―FALSE‖ (stop capturing).
10.1.2.2 Continuous mode
In this mode, when the AcquisitionStart command is set, the image is continuously
output at the current frame rate. This is the default setting for the AD-130GE.
1) AcquisitionStart command is input
2) AcquisitionTriggerWait becomes effective
3) AcquisitionActive becomes
“
TRUE
”
4) Images begin outputting continuously
5) AcquisitionEnd command is sent
6) AcquisitionActive becomes
“
FALSE
”
. At this moment, the output stops.
Fig.32 Continuous timing
This drawing shows a case where the trigger is ―ON‖. If the trigger is OFF,
FrameActive becomes ―TRUE‖ at the same timing as AcquisitionActive.
AcquisitionStart
Acquisition
Trigger
Wait
AcquisitionActive
Acquisition
Trigger
Wait
AcquisitionStop
ExposureActive
CCD Readout
FrameActive
Stream Active
Frame 1
Frame N
AcquisitionStatus
AcquisitionStart
Acquisition
Trigger
Wait
Acquisition
Active
AcquisitionTriggerWait
ExposureActive
CCD Readout
FrameActive
Stream
Active
AcquisitionStatus