AM-201CL / AB-201CL
- 46 -
9.3. Save and load functions
The following commands are for storing and loading camera settings in the camera EEPROM.
Load settings.
LD.
This command will load previously stored settings to the camera. 3 user settings can be stored in
the camera EEPROM. 1 factory setting is also stored in the camera. The settings stored in the last
used user area are used as default settings at power up.
Save Settings.
SA.
This command will store the actual camera settings to 1 of the 3 user areas in the camera EEPROM.
EEPROM Area.
EA.
If received, the camera will return
the last used user area number.
9.4 Command list
Command
Name
Format
Parameter
Remarks
A - General settings and utility commands.
1
Camera Status
Request
ST
?<CR><LF>
Actual setting
2
Online Help
Request
HP
?<CR><LF>
Command list
3
Firmware
Version
VN
?<CR><LF>
3 digits
(e.g) 100 = Version
1.00
4
Camera ID
Request
ID
?<CR><LF>
max 12 characters
5
Model Name
Request
MD
?<CR><LF>
max 12 characters
6
User ID
UD
=[Param.]<CR><LF>
UD?<CR><LF>
User can save and
load free text.(12 or
less characters)
7
Error code
ERRER=[Param.]<CR><LF
>
ERRER?<CR><LF>
One of following values will be replied
from the camera
0=One-Push has not been finished yet.
1=Succeeded.
2=Error1. Green image was too bright.
3=Error2. Green image was too dark.
4=Error3. Timeout-error occurred.
B
– Image format control
1
Height
ETL
=[Param.]<CR><LF>
ETL?<CR><LF>
SC=1: :2 to1080
AB-201
:
2Line step
AM-201
:
1Line step
2
Offset Y
STL
=[Param.]<CR><LF>
STL?<CR><LF>
SC=1: :1 to 1079
AB-201
:
2Line step
AM-201
:
1Line step
3 Binning Vertical
BNC=[Param.]<CR><LF>
BNC?<CR><LF>
0=off
1=1x2,
Only AM-201CL