CM-141MCL/PMCL/-RA / CB-141MCL/PMCL/-RA
33
Command
Name
Format
Parameter
Remarks
C - Trigger mode
1
Trigger Mode
TR
=[Param.]<CR><LF>
TR?<CR><LF>
0=Normal (Continuous)
1=EPS(Edge pre select)
2=PWC(Pulse width control)
3=RCT
5=Smear Less EPS
2
Trigger Polarity
TP
=[Param.]<CR><LF>
TP?<CR><LF>
0=Active Low
1=Active High
3
Trigger Input
TI
=[Param.]<CR><LF>
TI? <CR><LF>
0=Camera Link
1=Hirose 12pin
D -Image Format
1
Bit Allocation
BA
=[Param.]<CR><LF>
BA?<CR><LF>
0=8bit, 1=10bit , 2=12bit
2
Scan Format
SC
=[Param.]<CR><LF>
SC? <CR><LF>
0=Full Frame, 1=2/3 Partial
2=1/2 Partial, 3=1/4 Partial
4=1/8 Partial,5= Variable
3
Variable partial
start line
STL
=[Param.]<CR><LF>
STL? <CR><LF>
1 to 1024
4
Variable partial
end line
ETL
=[Param.]<CR><LF>
ETL? <CR><LF>
8 to 1032
5
V-Binning
VB
=[Param.]<CR><LF>
VB?<CR><LF>
0=OFF
1=On
Only CM-
141MCL
E - Gain, Black and signal settings
1
Gain Level
GA
=[Param.]<CR><LF>
GA?<CR><LF>
-84 to 670
2
Black Level
BL
=[Param.]<CR><LF>
BL?<CR><LF>
255 to 767
F - Saving and loading data in EEPROM
1
Load Setttings
(from Camera
EEPROM)
LD
=[Param.]<CR><LF>
0=Factory area
1=User 1 area
2=User 2 area
3=User 3 area
Latest used
DATA AREA
becomes
default at
next power
up.
2
Save Settings
(to Camera
EEPROM)
SA
=[Param.]<CR><LF>
1=User 1 area
2=User 2 area
3=User 3 area
Note : 0 is not allowed
3
EEPROM
Current Area No
Request.
EA
?<CR><LF>
0=Factory area
1=User 1 area
2=User 2 area
3=User 3 area
The camera
return the
latest used
DATA AREA.
NOTE: Do not try to use commands not shown in this list.