Technical Specifications
Item no. 10406075-S3, Revision 01
29 ( 52 )
6.10
Eddy current sensor (SGS, optional accessory)
Order number
1-001
6.10.1
Measurement principle
The displacement measurement system operates without contact on the basis
of an eddy current.
An electromagnetic coil field induces eddy currents and this causes the resis-
tance of the built-in coil to change.
q
An electrical signal is produced from this change.
q
The controller conditions the signal ready for the user.
6.10.2
Technical Specifications
The specified data are valid for
a reference temperature of
20°C.
Measurement range
400 µm
Start of measurement range
~ 150 µm
Linearity
± 5 µm
Resolution
1 µm
Limit frequency (analog)
20 mV / µm
Sensitivity
q
Displacement
q
Temperature
20 mV / µm
0.1 V / °C
Temperature stability
q
Sensor
q
Controller
± 0.01% of measurement range / °C
± 0.05% of measurement range / °C
Interfaces
q
Analog
q
Digital
0.2 ... 10 V
DC
(optional: 4 ... 20 mA)
on request
Temperature output
0.2 … 10 V
DC
Supply voltage
+24 V
DC
Sensor
EMU 04-C080
Parameter memory and temperature sensor integrated
in sensor housing
Sensor replace-
ment
Sensor-specific data record is read out automatically
from the EEPROM
cable length
q
Sensor
q
ECM6
0.8 m
6 m