MINI CANAL DBE 

OPTIONS

IMPORTANT

Incorrect positioning or installation of the unit may amplify noise 

levels and vibrations generated during operation or cause the unit 

to run badly, with a consequent deterioration in performance. 

Always use personal protective equipment.

Electrical connections

The electrical connection of the unit must be carried out by quali-

fied personnel, in compliance with the regulations applicable in the 

country where the unit is installed.

Non-conforming electrical connections releases Jaga N.V. from li-

ability concerning damage to objects and persons.

Hydraulic connection

IMPORTANT!

 The hydraulic connections must be carried out only by 

qualified personnel, adequately experienced.

Connection to the hydraulic system: 

Connect the unit to the hy-

draulic system with the indicated inlet/outlet connections. Make 

sure the connections are air tight with a sealant.

Please follow these instructions carefully in order to allow for an 

error-free installation and a carefree use. 

OPTION: 

Protection panel.

CODE: 7961.000L.LLBB

To prevent damage to the components: 
• Place the (optional) protection panel as  protection on the  

construction site

• Remove the protection panel before using the heating device!

INCLUDED AS STANDARD:

1 set = 3 pieces

Sealing plugs Ø 30 mm

1 set  Anchoring hooks

OPTION:

Height adjustment

4.5

1 set = 

Sets per unit length

2 sets

L

L 110 cm

3 sets

L 130 < > 190 cm

4 sets

L 210 cm

5 sets

L 230 < > 310 cm

CODE

(1 set) 7690.01

H

0 ↓↑ 4.5 cm

(1 set) 7690.04

4.5 ↓↑ 13 cm

Acoustical insulation

Insulation against airborne noise:

Sound is reflected by hard materials. Soft, porous substances are 

best suited to absorbing airborne sound. 

Contact sound insulation:

Sound travels very easily in hard materials. Contact sound insula-

tion will largely depend on this: 

A. Quality of the placement:

Contact points.

• 

 Make sure that sound- and/or mechanical vibrations cannot be 

transferred between different elements, e.g. between the built-

in heaters and a metal carrier, through pipes, along air ducts etc. 

Hollow acoustic spaces

.

• 

 Where air can travel, so can sound:

  Isolate the built-in heaters in hollow acoustic spaces. Avoid cavi-

ties between insulation and pipes. These form small resonance 

boxes. Avoid cavities along air ducts (the acoustic effect cannot 

be predicted for this).

Heat Exchanger

Fan

!! ATTENTION !!

20 cm

Hoogteregeling

• Install the MINI CANAL DBE with the heat exchanger to the wall 

side !

• Foresee sufficient space for curtains

Height adjustment

Содержание MINI CANAL DBE

Страница 1: ...MINI CANAL DBE HEATING COOLING CONTROL PANEL DPC MD44 Please read this manual carefully before installing Manual...

Страница 2: ...panel Water temperature sensor 7 OPTIONS Integrated power supply Separate adapter Dimensions B L 26 110 130 150 170 190 210 230 250 270 290 310 34 110 130 150 170 190 210 230 250 270 290 310 42 110 1...

Страница 3: ...protection on the construction site Remove the protection panel before using the heating device INCLUDED AS STANDARD 1 set 3 pieces Sealing plugs 30 mm 1 set Anchoring hooks OPTION Height adjustment 4...

Страница 4: ...ance of the device a lot easier USE PFTE TAPE 110 230V AC 50 60 Hz 1 5 mm2 16 AWG OPTION 12 V 12 V 1 2 MODE 3 230 V 12 V 1 2 MODE 3 12 V DC 0 F E D C B A 987 6 5 4 3 2 1 Adapter Control unit Preferabl...

Страница 5: ...m Nm 2 5 4 Attach the two pin plug Assembly and turning until click Turn a half stroke clockwise 6 Fill up with concrete 7 Finish with silicone 8 Place the grille FILL UP 5 Place the spacers Z profile...

Страница 6: ...hanger 3 the hydraulic piping are clean and purge 4 the heat exchanger and fans are clean 5 the supply voltage is correct Maintenance Instructions for maintenance Routine maintenance Cleaning the duct...

Страница 7: ...atertemperature is higher as the de preset water temperature This indicates that the water supply is hot Each adjustment will be stored in internal EE PROM memory C Exit setup mode by pressing the but...

Страница 8: ...ent for the treatment of air in indoor environments The units comply with the following Directives 2006 42 EC Machinery Directive low voltage Directive 2006 95 EC electromagnetic compatibility Directi...

Отзывы: