93
EN
INSTALLATION
For general safety information see: warnings and safety -
page 84
ALWAYS USE THE MAIN SWITCH TO ISOLATE THE POWER SUPPLY
Remove the cover panel before installing the appliance.
Position the external heigth adjustment and bolt to the trench. Do
not tighten the bolt yet.
Position the acoustic insulation over each floor bracket.
Install the leveling screws in the trench and mount the plastic caps
to the screws.
For continuous installation only: Remove the stainless steel trim on
the end caps bij breaking of the pre-cut piece.
Only remove the trim pieces on the side where another
trench will be connected.
01
03
02
04
05
If multiple Clima Quatro Canals, empty sections or corner 05
pieces have to be connected in a continuous installation,
continue to step 05.
Or individual installations: continue to step 07.
POSITIONING
Содержание Clima Quatro Canal H19
Страница 2: ...NL PG 3 PG 29 PG 55 PG 81 FR DE EN 2...
Страница 3: ...INSTALLATIEHANDLEIDING Clima Quatro Canal H19 3...
Страница 29: ...INSTRUCTION D INSTALLATION Clima Quatro Canal H19 29 29...
Страница 55: ...INSTALLATIONHINWEIS Clima Quatro Canal H19 55...
Страница 81: ...INSTALLATION INSTRUCTIONS Clima Quatro Canal H19 81...
Страница 107: ...107 EN NOTES...