background image

 

 

 

OPERATION AND MAINTENANCE MANUAL 

12-2015 

 

 
 
 
 
 

Operation and Maintenance Manual 

 

 

BREAK-AWAY FIRE HYDRANT 

 

P/N 

TYPE 8003

 

 
 
 
 
 

 

 

Approved for use by  

 

President of Factory, JAFAR S.A. 

 
 
 

Failure  to  comply  with  the  guidelines  and  instructions  in  this  Operation  and 

Maintenance Manual releases the manufacturer from all obligations, liability and guarantee. 
 

Due  to  continuous  business  development,  we  reserve  the  right  to  introduce 

modifications and structural changes to the presented product. 
 

 
 

Содержание 8003

Страница 1: ...President of Factory JAFAR S A Failure to comply with the guidelines and instructions in this Operation and Maintenance Manual releases the manufacturer from all obligations liability and guarantee Du...

Страница 2: ...3 DIMENSIONS DN80 8 2 4 MATERIALS DN100 9 2 5 DIMENSIONS DN100 10 2 6 STANDARDS 11 2 7 ORDERING REGULATIONS 11 2 8 MANUFACTURE AND ACCEPTANCE 11 2 9 MARKINGS 12 3 PROTECTION STORAGE TRANSPORT 12 3 1 P...

Страница 3: ...drant clockwise closing sense of rotation The closing sense of rotation can be opposite on special order connection flanges are manufactured in accordance with PN EN 1092 2 1999 with the dimensions ad...

Страница 4: ...derground part of the hydrant The rotating stem is seated in a stopper with rubber sealing rings Rotate the hydrant clockwise to close the flow Poppet moves during rotation of the stem and flow opens...

Страница 5: ...OPERATION AND MAINTENANCE MANUAL 12 2015 5 Operation diagram for hydrant TYPE 8003 DN80 CLOSE OPEN...

Страница 6: ...hydrant TYPE 8003 DN100 CLOSE OPEN The order of operations during opening and closing of a hydrant type 8003 configured with a shutoff gate valve Starting 1 Open the shutoff gate valve 2 Open the hyd...

Страница 7: ...2003 PN EN 10088 1 2014 4 Seat Brass PN EN 1982 2010 5 Poppet Cast iron EN GJS 400 15 EN GJS500 7 EPDM PN EN1563 2012 PN ISO1629 2005 6 Cap Cast iron EN GJS 400 15 EN GJS500 7 PN EN1563 2012 7 Stem St...

Страница 8: ...OPERATION AND MAINTENANCE MANUAL 12 2015 8 2 3 DIMENSIONS DN80 DN RD L H H1 H2 H3 Weight kg 1250 1890 2055 1130 75 1500 2140 2305 1380 81 1800 2440 2605 1680 89 80 600 110 mm...

Страница 9: ...SO1629 2005 6 Cap Cast iron EN GJS 400 15 EN GJS500 7 PN EN1563 2012 7 Stem Stainless steel 1 4021 PN EN 10088 1 2014 8 Spindle Stainless steel 1 4301 PN EN 10088 1 2014 9 Saddle tee Aluminium AlSi PN...

Страница 10: ...OPERATION AND MAINTENANCE MANUAL 12 2015 10 2 5 DIMENSIONS DN100 DN RD L H H1 H2 H3 Weight kg 1250 1890 2075 1125 85 1500 2140 2325 1375 90 1800 2440 2625 1675 96 100 600 110 mm...

Страница 11: ...ose metric screw threads Tolerances Principles and basic data PN ISO 2903 1996 Trapezoid ISO metric threads Tolerances PN EN ISO 4762 2006 Hexagon socket headcap screws PN EN ISO 4017 2011 Hexagon hea...

Страница 12: ...meplate which contains the following data manufacturer s company name and logo product serial number sealing temperature grade the Polish Building Mark B and or the CE mark as applicable product type...

Страница 13: ...medium water supply The hydrant is equipped with special flanges to enable free above ground part s rotation from 0 to 360 Special bolts for connecting the lower part with the above ground part if th...

Страница 14: ...n i e application for media and operation parameters of the pipeline in which they are to be installed Note If the product is damaged mechanically do not install it in the pipeline Any change in the o...

Страница 15: ...xceeding the operating limits of the fitting may result in damage that will not be covered by the suretyship granted by the manufacturer It is recommended to change the hydrant s settings once a year...