4. Adjustments and Settings
4-1 Model setting
1
) Turn on the power while pressing key
SMPL
.
2) Key in 1130 with the numeric keys.
3) Again press key
SMPL
to confirm.
4) Press numeric key
1
to set maximum capacity. Available options are:3/6/15/30(kg).
5) Press numeric key
2
to select version. Available options are: TW/CN.
6) Press key
SMPL
, then press key
ZERO
to go back to weighing mode.
4-2 Single Point Calibration
1) Press and hold key
SMPL
while powering on the scale.
2) Input 11 with numeric keys.
3) Again press key
SMPL
to enter the zero point calibration modes.
4) Wait till “
” flashes, press numeric key
1
to select calibration weight .Options are
1/3 of full load, 2/3 of full load and full load. E.g., options for JCL-15K are 5, 10 and 15(kg).Put
the corresponding weights on the weighing pan.
5) Press key
·
to confirm.
6) The calibration procedure is completed with a “
remove all the weights.
” flashing on the weight screen. Now,
7) Press key
SMPL
to save
,
and then press key
ZERO
to return to the weighing mode.
4-3 Linear Calibration
1) Press and hold key
TARE
while powering on the scale.
2) Again press key
TARE
to enter zero point calibration mode, with “
weight screen.
12 JCL Service
Manual