9.  Flush  your  system  prior  to  installing  the  shower 
head.  Place handle on valve stem and turn handle to 
full mix position.  Turn ON water supplies, check for 
leaks and let lines 

fl

 ush for one minute without moving 

faucet handle. Divert water to shower head and 

fl

 ush 

for 30 seconds.  This will remove any debris from lines 
which  can  damage  internal  parts  of  the  faucet  and 
create leaks.  After 

fl

 ushing, shut OFF water at faucet.  

Remove handle and attach escutcheon.  Attach shower 
head.

CAUTION: 

Connection of deck-mount spouts to in-

wall valves is not recommended.  Neither is the use of 
hand showers connected to bath spouts in a bath/shower 
push button diverter combination.

 

©1995   Jacuzzi Whirlpool Bath   G570000   D   12/06 

Page 3

8.  Slide bonnet nut (1) over the cartridge and thread 
onto the body. Hand tighten securely. 

1

10.  IMPORTANT: The Rotational Limit Stop is used to 
limit the amount of hot water available such that, if set 
properly, the user will not be scalded if the handle ac-
cidentally is rotated all the way to “hot” when a person 
is showering or 

fi

 lling a tub. The 

fi

 rst position allows the 

LEAST amount of hot water to mix with the cold water 
in the system. In the 

fi

 rst position the water will be the 

coldest possible when the handle is turned all the way to 
hot. As you move the Rotational Limit Stop counterclock-
wise, you progressively add more and more hot water 
in the mix. The last position to the left will result in the 
greatest amount of hot water to the mix, and the great-
est risk of scald injury if someone accidentally turns the 
valve handle all the way to the hot side while showering 
or 

fi

 lling a tub.

1st Position

Hotter

Rotational Limit Stop

Stem

Disc

Colder

WARNING: In some instances, setting the Rotational 
Limit Stop in the hottest position (full counterclock-
wise) could result in scald injury. It is necessary to 
adjust the Rotational Limit Stop so that the water 
coming out of the valve will not scald the user when 
the handle of the valve is rotated to the hot side.

Adjust rotational limit stop.   After water has run a suf

fi

 cient 

length of time so that cold water is as cold as it will get, 
and hot water is as hot as it will get, place handle back 
on stem and rotate handle counter clockwise to the hot-
test position.  Place a thermometer in a plastic tumbler, 
and hold the tumbler in the water stream.  Record the 
temperature reading and note or mark the position of 
the Rotational Limit Stop on the mating part.  If the water 
temperature is above 120°F the Rotational Limit Stop 
must  be  rotated  clockwise  to  reduce  the  temperature 
(See illustration).

Remove the Rotational Limit Stop and replace it one tooth 
counter clockwise for every 6° F (approximate) reduction 
in temperature that must be made.  If water temperature 
is below 90° F, rotate the stop counter-clockwise.  Repeat 
as necessary.  Make sure cold water 

fl

 ows from the valve 

fi

 rst and does not exceed 120°F at the hottest 

fl

 ow.  A 

guide to setting the approximate outlet temperature is 
included.  This is only a guide and any setting must be 
veri

fi

 ed by using the above procedure.