background image

INSTALLATION INSTRUCTIONS

WARNING: 

Failure to follow these instructions could 

prevent  the  mixer/transfer  valve  from  functioning 
properly.
1.  Shut OFF water supplies. 
2.  Install the body (1) so the surface of the 

fi

 nished 

wall  is 

fl

 ush  with  the  front  of  the  plasterguard  (2). 

The  plasterguard  is 
mounted on the body 
using the two stringer 
mounting holes (3) on 
the  bracket. 

NOTE: 

Remove cover (4) to 
access body  mount-
ing holes.

 Ensure the 

word "UP" (5) is on top 
of the valve body when 
installing.
3. Install transfer valve 
so that the transfer valve inlet connects to the top port 
of the mixer valve.  See below. The transfer valve must 
be located at least 4-15/16" (center to center) away from 
the  mixer  valve.   A  left-hand  thread  to  sweat  adaptor 
and gasket are required for this connection.  Use a 1/2" 
copper pipe size, a taper to sweat adaptor, and a female 
thread to sweat adaptor to 

fi

 nish the connections from 

transfer valve to mixer valve.  Copper pipe and adaptors 
not provided.
Connect hot and cold supply lines to left and right inlets of 
mixer body.  Left is hot and right is cold (as viewed from 
front).  Threaded inlets are 1/2" NPT (iron pipe size).  Use 
an approved thread sealant for threaded connections.  
Remove bonnet (1) and test cap (2) before soldering.  
Leave screen (3) installed.  

WARNING: Avoid soldering 

at high temperature.  Exposure to high temperatures 
may damage screen. 

 

4.  Rotate the cartridge (1) so the words “hot side” (2) 
appear on the left. Insert cartridge into valve body as 
shown.  Make sure the cartridge tubes and o-rings (3) 
are  properly  seated  in  holes  at  the  base  of  the  body.   
Ensure the keys on the body are fully engaged with the 
slots in the body (4).
For  shower  head 
installation  connect  
plumbing  from  top 
outlet of transfer valve 
to  shower  head  arm 
with proper 

fi

 ttings.  Do 

NOT install the shower 
head onto arm at this 
time.

5.  For cascade installation connect right outlet of transfer 
valve to cascade line.   The left outlet is for body spray jets.  
Plug unused ports if other arrangements are used.  

COLD IN

HOT IN

TO

CASCADE

TO

BODY

SPRAY

TO SHOWER

TRANSFER

VALVE

MIXER VALVE

*COPPER PIPE

M

x

F ADAPTER (3) 

COPPER GASKET (4)

OPTICA 300 CONNECTIONS

*LEFT-HAND

THREAD TO 

SWEAT ADAPTER

*FEMALE

THREAD TO

SWEAT ADAPTER

*NOT PROVIDED

1

2

3

HOT

COLD

REVERSE

INSTALLATION

NORMAL INSTALLATION

(CHANGES NOT REQUIRED)

BACK TO BACK OR REVERSE INSTALLATION

TRANSFER VALVE

TRANSFER 

VALVE

Page 2 

©1995   Jacuzzi Whirlpool Bath   G570000   D   12/06

4

1

2

3

3

5

1

4

4

2

3

6. 

For

 

back to back or reverse installations only

 

(hot on right and cold on left), follow instructions below.  
If you are not making a reverse or back to back instal-
lation skip Steps 6 and 7 and continue with Step 8.
Make sure water supplies are OFF.  Install mixing valve 
as directed in the previous steps.    
7. 

For

 

back to back or reverse installations only

  

(hot  on  right  and  cold  on  left).  Connect hot and cold 
supply lines to left and right inlets of mixer body.  

Right 

is hot 

and

 left is cold

 (as viewed from front).  

Отзывы: