background image

Shower Base Installation And Operation 

www.jacuzzi.com

 

Page 5

    English 

 

Do not lift a corner to level the base. This will result in loss of contact with the mortar.

 

 

Attach the shower base flange to the stud wall and blocking with the stainless-steel screws provided. Use a minimum of three  

 

screws per flange section, see Figure 4. If there is a gap between the base flange and the stud or blocking, a shim must be  

 

used to prevent distortion or cracking of the flange. 

 

Use the stainless-steel screws provided. 

 

If there is any gap between the base flange and stud or blocking, shims must be used.

 

 

Tighten the drain as directed by the instructions that came with the drain kit. After the drain is fully installed, test for proper  

 

drainage. 

 

If the shower base does not drain properly, correct this condition before proceeding with the installation.   

 

Watertight installation is the installer’s responsibility, as drain leakage is excluded from the Warranty. Jacuzzi

®

 is 

not responsible for reinstallation costs. 

 

 

Replace the strainer, if your drain kit came with one, and tape over the drain  

 

hole to prevent finishing material from entering the drain. Place a  

 

 

 

cement board or equivalent on top of the shower base flange and  

 

 

 

secure to studwall, see Figure 5.

 

 

Apply tile, or other finishing material, leaving a 1/8” gap between the  

 

 

finishing  material and the flange lip of the shower base. Seal this gap with  

 

a silicone sealant. Leave a minimum 1/4” weep hole at the back and front  

 

corners of the shower base, see Figures 6 and 7.

 

Add 100% silicone under the tile and backer board on top of the dam only  

 

(see Figures 3 and 6). Refer to local building codes for proper finishing or other trades.

  

CAUTION

IMPORTANT

Installation Instructions

  

CAUTION

5

Figure 4

INCORRECT

INCORRECT

CORRECT

Blocking

Base flange

Use screws 

provided

Gap

Stud

Blocking

Base flange

Use screws 

provided

Láminilla de 

nivelación

Stud

Blocking

Base flange

Use screws 

provided

Stud

Láminilla de 

nivelación

Figure 5

Cement board

Blocking

Silicone sealant

1/4” Min Weep Hole

Leave drain valley clear 

of silicone

Figure 6

100% Silicone under

tile on top of dam sealing

the front perimeter from any 

possible water passage.

1/8” Gap

Tile

Cement 

board

Tile 

adhesive

Blocking

1/4” Min Weep Hole

Silicone sealant

Figure 7

  

CAUTION

6

7

8

Содержание 3636S

Страница 1: ...E124000Y 6 2013 INSTALLATION AND OPERATION INSTRUCTIONS Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino CA 91710 1 800 288 4002 www jacuzzi com SHOWER BASES...

Страница 2: ...mber for future reference Date Purchased Purchased From Installed By Serial Number Model Installer Leave the manual for the homeowner Homeowner Read this manual and keep for future reference Product I...

Страница 3: ...5 30 00 50 lb T354000 3642S 36 42 20 25 18 00 28 lb T374000 4832S 48 32 15 00 24 00 29 lb T232000 4234S 42 34 16 50 21 00 27 lb T228000 6034S 60 34 16 50 30 00 39 lb NEO ANGLE T358000 3838N 38 38 14 5...

Страница 4: ...Figure 1 If the subfloor is level no other preparation is necessary Proceed to install the base If the subfloor is not level level the shower base by spreading a floor leveling compund mortar plaster...

Страница 5: ...kit came with one and tape over the drain hole to prevent finishing material from entering the drain Place a cement board or equivalent on top of the shower base flange and secure to studwall see Fig...

Страница 6: ...automotive rubbing compound followed by an application of automotive paste wax Major scratches and gouges that penetrate the acrylic surface may require refinishing Ask your Jacuzzi Luxury Bath deale...

Страница 7: ...improper cleaners or acts of God such as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g...

Страница 8: ...ed Service Agent call or write Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino California 91710 Call 800 288 4002 To obtain warranty replacement for factory installed components or Company supplied...

Страница 9: ...uzzi Base para Ducha Instalaci n y Operaci n www jacuzzi com Page 9 INSTRUCCIONES DE INSTALACION Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino CA 91710 1 800 288 4002 www jacuzzi com BASE PARA DU...

Страница 10: ...de el n mero de modelo y serie de su unidad abajo Instalador Deje este manual al propietario Propietario Lea este manual y gu rdelo para referencia Conserve estas instrucciones para uso futuro Install...

Страница 11: ...000 6042S 60 42 20 25 30 00 50 lb T354000 3642S 36 42 20 25 18 00 28 lb T374000 4832S 48 32 15 00 24 00 29 lb T232000 4234S 42 34 16 50 21 00 27 lb T228000 6034S 60 34 16 50 30 00 39 lb Neo Angular T3...

Страница 12: ...Figura 1 Si el subsuelo est nivelado no se necesita ninguna preparaci n Seguir a instalar la base Si el subsuelo no est nivelado poner un compuesto para nivelar el suelo como mortero yeso o espuma exp...

Страница 13: ...del drenaje con cinta para que no entra el sucio de los materiales de instalaci n Colocar un pared de cemento o equivalente encima del borde de la base y asegurarlo al entramado ver Figura 5 Aplicar e...

Страница 14: ...afectan la superficie acr lica puede requerir un reacabado Mejor contactar su distriuidor Jacuzzi Luxury Bath para instrucciones PRECAUCI N Dimensiones para Preparaci n de Instalaci n Solo Neo Angular...

Страница 15: ...e se especifica o a una temperatura del agua inadecuada uso de limpiadores abrasivos o improprios o desastres naturales como rel mpagos inundaciones terremotos etc Ademas la COMPA A NO SER RESPONSABLE...

Страница 16: ...d y le ofrecer el servicio que requiere la garant a En caso de que no peuda ocnseguir a un Agente de Servicio Autorizado de Jacuzzi Luxury Bath escriba o llame a Jacuzzi Luxury Bath 14525 Monte Vista...

Отзывы: