22
Optional Air Conditioner Installation
Disconnecting Battery.
Disconnect the battery. Be sure to follow safety
precautions.
——————————————————————————————————
Removing Alternator.
Remove the alternator and alternator belt tensioner. Save
hardware for later re-installation.
——————————————————————————————————
Drill out belt tensioner hole to 3/8” wide.
——————————————————————————————————
Installing new compressor.
Install new compressor on top mounting location,
where the alternator was originally located. Use new provided belt tensioner to
mount to factory location and onto compressor.
——————————————————————————————————
Re-installing alternator.
Take alternator and original tensioner and mount to
bottom of bracket. Use bottom compressor mount hole for tension as shown,
using the M10 X 100 X 1.5mm carriage bolt.
——————————————————————————————————
Replacing main V-Belt.
Replace main V-Belt with 31/64” X 52 3/8” V-Belt
(12.5mm X 1330mm)
——————————————————————————————————
Installing alternator and compressor V-Belt.
Use the 1/2” X 24 1/2” (13mm X
620mm) V-Belt for alternator and compressor pulley.
——————————————————————————————————