PARTS
MOTOR OVERLOADS
WASH MOTOR
VOLTAGE
PART NUMBER
GE PART NUMBER
208
05945-004-35-45
RT1N
230
05945-004-35-45
RT1N
460
05945-111-81-33
RT1L
600
05945-111-68-41
RT1K
DRIVE MOTOR
VOLTAGE
PART NUMBER
GE PART NUMBER
208
05945-111-68-39
RT1G
230
05945-111-68-39
RT1G
460
05945-002-71-09
RTN1F
600
05945-111-68-39
RT1G
Pre-wash MOTOR
VOLTAGE
PART NUMBER
GE PART NUMBER
208
05945-111-68-40
RT1M
230
05945-111-68-40
RT1M
460
05945-111-68-41
RT1K
600
05945-111-68-41
RT1K
WASH MOTORS:
Overloads are specified for 3-phase units only.
For GE brand MT03* series overloads, the process for setting is as follows:
• Determine the Full Load Amps (FLA) for the wash motor.
• Set the overload at the closest setting without going over for the FLA of the motor.
•
The overload already compensates for the FLA and will have a setpoint that is 125% of the FLA. (Example: Wash motor
is rated at 10.0 FLA on the data plate. The replacement MT03* overload will be set at 10.0. It will trip at 12.5 Amps.)
Blue selector switch should be
set to H for manual reset.
DRIVE MOTORS:
Overloads are specified for 3-phase units only.
For GE brand MT03* series overloads, the process for setting is as follows:
• Determine the FLA for the drive motor.
• Set the overload at the closest setting without going over for the FLA of the motor.
•
The overload already compensates for the FLA and will have a setpoint that is 125% of the FLA. (Example: Drive motor
is rated at 1.0 FLA on the data plate. The replacement MT03* overload will be set at 1.0. It will trip at 1.25 Amps.)
Blue selector switch should be
set to H for manual reset.
PRE-WASH MOTORS (66 ONLY):
Overloads are specified for 3-phase units only.
For GE brand MT03* series overloads, the process for setting is as follows:
• Determine the FLA for the Pre-wash motor.
• Set the overload at the closest setting without going over for the FLA of the motor.
•
The overload already compensates for the FLA and will have a setpoint that is 125% of the FLA. (Example: Pre-wash
motor is rated at 6.0 FLA on the data plate. The replacement MT03* overload will be set at 6.0. It will trip at 7.5 Amps.)
Blue selector switch should be
set to H for manual reset.
Connections should be tightened to 7 in-lbs.