07610-004-33-05-E
33
OBSERVATION
POSSIBLE CAUSE
REMEDY
No indication of
pressure.
1. Water turned off.
2. Pressure transducer
disconnected.
3. Pressure transducer defective.
1. Turn water on.
2. Verify wiring.
3. Replace pressure transducer.
Wash water is not
reaching required
temperature.
1. Faulty wash heater.
2. Wash thermometer is defective.
1. Check element for continuity; if open, replace the heater.
2. Replace thermometer.
Doors will not close
completely.
1. Obstruction in door channel.
2. Machine not level.
1. Remove the obstruction.
2. Adjust the feet to level machine.
Water leaks at the
wash pump.
1. Wash pump seal defective.
2. Pump drain hose not tight.
3. Loose hoses (hose clamps) on
the wash pump.
1. Replace the seal.
2. Tighten.
3. Tighten the hose clamps.
Will not rinse.
1. Defective rinse solenoid.
2. Faulty timer.
3. No water to the machine.
1. Repair or replace the rinse solenoid.
2. Replace timer.
3. Verify that there is water at 15 PSI connected to the
machine.
Dishes are not
coming clean.
1. Machine temperatures are not up
to the minimum requirements.
2. No detergent or too much
detergent.
1. Verify that incoming water, rinse water, and wash water
match the required temperatures listed on the machine
data plate.
2. Adjust detergent concentration as required for the
amount of water in the machine.
WARNING!
Inspection, testing, and repair of electrical equipment should only be performed by a
qualified service technician. Many of the tests require that the unit have power to it and live electrical
components be exposed. USE EXTREME CAUTION WHEN TESTING THE MACHINE.
!
WARNING
TROUBLESHOOTING
TROUBLESHOOTING
Содержание RackStar 44
Страница 62: ...07610 004 33 05 E 54 PARTS RINSE SYSTEM 1 2 3 4 5 6 7 4 3 3 3 5 5 5 1 8 9 11 10 12 12 13 14 ...
Страница 89: ...07610 004 33 05 E 81 SCHEMATICS SIDE LOADER ...
Страница 91: ......