21
07610-004-29-29-A
F12 Service needed –
check booster thermo-
stat
Faulty temperature probe (T3).
Replace probe that connects to P13.
F13 Communication er-
ror. Check 6-pin cable
1. Loose connection in 6-pin cable between
display board and IO module.
2. Faulty 6-pin cable between display board
and IO module.
3. Faulty communication port on IO module or
display board.
1. Fully disconnect 6-pin cable at each end, and reconnect
each end until a click is heard.
2. Inspect for broken wire or unseated terminal by gently
pulling on each wire at each end of the cable. Reseat any
loose terminals by inserting it fully into the housing using
long-nosed pliers. Replace cable if broken wire is found.
3. Temporarily substitute a verified good display board, and
check if F13 message recurs. If so, repeat substitution with
a good IO module.
DISPLAY SHOWS
POSSIBLE CAUSES
REMEDY
FAULT CODES
TROUBLESHOOTING
TABLE 1: RESISTANCE-TO-TEMPERATURE VALUES
R (kΩ)
°F
11.58
69.8
10.37
75.2
9.30
80.6
7.78
89.6
3.05
140.0
2.54
150.8
2.18
159.8
1.58
179.6
1.45
185.0
1.33
190.4
1.16
199.4
0.96
212.0
Содержание DynaTemp
Страница 2: ......
Страница 35: ...28 07610 004 29 29 A TUB ASSEMBLY PARTS 12 11 10 13 14 20 21 4 19 18 17 15 16 1 2 3 5 6 7 8 9 ...
Страница 37: ...30 07610 004 29 29 A STEAM TUB ASSEMBLY PARTS 12 11 14 20 21 4 19 18 17 16 1 2 3 5 7 8 9 6 13 15 10 ...
Страница 54: ...47 07610 004 29 29 A PARTS WASH RINSE ARM ASSEMBLIES 7 15 12 11 17 10 4 14 13 9 19 16 1 2 3 4 5 6 4 8 18 ...
Страница 63: ...56 07610 004 29 29 A DRAIN QUENCH OPTION SCHEMATICS ...
Страница 67: ......