4
07610-004-29-29-A
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical
service contractor that your circuit protection is adequate and meets all applicable national and local codes.
Numbers in this manual are for reference and may change without notice.
VOLTS PHASE
HZ
RINSE HEATER
RATINGS
TOTAL
AMPS
TYPICAL
ELECTRICAL CIRCUIT
208
1
50
12 kW@240 V
71 A
90 A
208
1
50
14 kW@240 V
78 A
100 A
230
1
50
12 kW@240 V
78 A
100 A
230
1
50
14 kW@240 V
86 A
110 A
NOTE: Typical Electrical Circuit is based on:
1. 125% of the full amperage load of the machine.
2.
Typical fixed-trip circuit breaker sizes as listed in the NEC (Latest
Edition).
208
3
50
12 kW@240 V
45 A
60 A
208
3
50
14 kW@240 V
49 A
70 A
230
3
50
12 kW@240 V
48 A
60 A
230
3
50
14 kW@240 V
53 A
70 A
380
3
50
12 kW@380 V
29 A
40 A
380*
3
50
14 kW@240 V
34 A
45 A
415
3
50
12 kW@415 V
26 A
35 A
415
3
50
14 kW@415 V
29 A
40 A
440
3
50
12 kW@460 V
21 A
30 A
440
3
50
14 kW@460 V
25 A
35 A
208
1
60
12 kW@240 V
69 A
90 A
208
1
60
14 kW@240 V
76 A
100 A
230
1
60
12 kW@240 V
76 A
100 A
230
1
60
14 kW@240 V
84 A
110 A
208
3
60
12 kW@240 V
43 A
60 A
208
3
60
14 kW@240 V
47 A
60 A
230
3
60
12 kW@240 V
46 A
60 A
230
3
60
14 kW@240 V
51 A
70 A
460
3
60
12 kW@480 V
22 A
30 A
460
3
60
14 kW@480 V
25 A
35 A
* This model is wired in a wye configuration for the heaters.
NOTICE
i
Содержание DynaTemp NB
Страница 2: ......
Страница 35: ...28 07610 004 29 29 A TUB ASSEMBLY PARTS 12 11 10 13 14 20 21 4 19 18 17 15 16 1 2 3 5 6 7 8 9...
Страница 37: ...30 07610 004 29 29 A STEAM TUB ASSEMBLY PARTS 12 11 14 20 21 4 19 18 17 16 1 2 3 5 7 8 9 6 13 15 10...
Страница 54: ...47 07610 004 29 29 A PARTS WASH RINSE ARM ASSEMBLIES 7 15 12 11 17 10 4 14 13 9 19 16 1 2 3 4 5 6 4 8 18...
Страница 63: ...56 07610 004 29 29 A DRAIN QUENCH OPTION SCHEMATICS...
Страница 67: ......