![Jackson Delta HT-E-SEER-S Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/jackson/delta-ht-e-seer-s/delta-ht-e-seer-s_installation-operation-and-service-manual_628857034.webp)
27
07610-004-54-86-D
F12 - Not Used
N/A
N/A
F13 Communication
error. Check 6-pin
cable
1. Loose connection in 6-pin cable between
display board and I/O module.
2. Faulty 6-pin cable between display board
and I/O module.
3. Faulty communication port on I/O module
or display board.
1. Fully disconnect 6-pin cable at each end, and reconnect
each end until a click is heard.
2. Inspect for broken wire or unseated terminal by gently
pulling on each wire at each end of the cable. Reseat any
loose terminals by inserting it fully into the housing using
long-nosed pliers. Replace cable if broken wire is found.
3. Temporarily substitute a verified good display board, and
check if F13 message recurs. If so, repeat substitution with
a good I/O module.
DISPLAY SHOWS
POSSIBLE CAUSES
REMEDY
FAULT CODES
TROUBLESHOOTING
RESISTANCE-TO-TEMPERATURE VALUES
R (kΩ)
°F
11.58
69.8
10.37
75.2
9.30
80.6
7.78
89.6
3.05
140.0
2.54
150.8
2.18
159.8
1.58
179.6
1.45
185.0
1.33
190.4
1.16
199.4
0.96
212.0