Jackson Delta HT-E-SEER-S Скачать руководство пользователя страница 3

MANUFACTURER'S LIMITED WARRANTY (CONT.)

(APPLICABLE ONLY IN THE UNITED STATES AND CANADA)

PRODUCT CHANGES:

Jackson reserves the right to make changes in design and specification of any component of the Dishmachine as 

engineering or necessity requires. 

DISCLAIMER OF WARRANTIES:

THERE ARE NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED 

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, THAT ARE NOT SET FORTH 

HEREIN, OR THAT EXTEND BEYOND THE DURATION HEREOF. 

LIMITATION OF REMEDIES AND LIABILITIES: 

YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR 

REPLACEMENT AS PROVIDED HEREIN.

UNDER NO CIRCUMSTANCES WILL JACKSON BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL 

DAMAGES, OR FOR DAMAGES IN THE NATURE OF PENALTIES.  JACKSON’S LIABILITY ON ANY CLAIM OF ANY 

KIND WITH RESPECT TO THE GOODS OR SERVICES COVERED HEREUNDER SHALL IN NO CASE EXCEED THE 

PRICE OF THE GOODS OR SERVICES OR PART THEREOF WHICH GIVES RISE TO THE CLAIM. 

ITEMS NOT COVERED: 

THIS WARRANTY DOES NOT COVER (1) ADJUSTMENTS INCLUDING, BUT NOT LIMITED TO, TIMER CAMS, 

THERMOSTATS, DOORS, TANK HEATER ADJUSTMENTS OR CLUTCHES; (2) AIR FREIGHT OR OVERNIGHT 

FREIGHT; (3) ANY AMOUNT EXCEEDING ORIGINAL PURCHASE PRICE; (4) CLEANING OF DRAIN VALVES, 

GAS LINES, RINSE/WASH NOZZLES, STRAINERS, SCREENS, OR SPRAY PIPES; (5) CLEANING OR DELIMING 

OF THE DISHMACHINE OR ANY COMPONENT INCLUDING, BUT NOT LIMITED TO, WASH ARMS, RINSE 

ARMS AND STRAINERS; (6) CONDITIONS CAUSED BY THE USE OF INCORRECT (NON-COMMERCIAL) 

GRADE DETERGENTS; (7) CORROSION FROM CHEMICALS DISPENSED IN EXCESS OF RECOMMENDED 

CONCENTRATIONS; (8) COSMETIC DAMAGE, INCLUDING BUT NOT LIMITED TO, SCRATCHES, DENTS, CHIPS, 

AND OTHER DAMAGE TO THE DISHMACHINE FINISHES, UNLESS SUCH DAMAGE RESULTS FROM DEFECTS IN 

MATERIALS AND WORKMANSHIP AND IS REPORTED TO JACKSON WITHIN (30) THIRTY DAYS FROM THE DATE 

OF INSTALLATION; (9) DAMAGE CAUSED BY LABOR DISPUTE; (10) DAMAGES RESULTING FROM IMPROPER 

CONNECTION TO UTILITY SERVICE; (11) DAMAGES RESULTING FROM WATER CONDITIONS, INADEQUATE OR 

EXCESSIVE WATER PRESSURE, ACCIDENTS, ALTERATIONS, IMPROPER USE, ABUSE, HANDLING, OVERLOADS, 

TAMPERING, IMPROPER INSTALLATION OR FAILURE TO FOLLOW MAINTENANCE AND OPERATING 

PROCEDURES; (12) DISCOLORATION, RUST OR OXIDATION OF SURFACES RESULTING FROM CAUSTIC 

OR CORROSIVE ENVIRONMENTS, INCLUDING, BUT NOT LIMITED TO, HIGH SALT CONCENTRATIONS, HIGH 

MOISTURE OR HUMIDITY, OR EXPOSURE TO CHEMICALS; (13) ELECTRIC BOOSTERS, FEED LINES, FLEX HOSE, 

FUSES, GARBAGE DISPOSALS, OR GAS PILOTS; (14) EXCESSIVE LIME, MINERAL, OR ALKALINE BUILDUP; (15) 

EXPENSES DUE TO DISCONNECTION, DELIVERY, RETURN AND REINSTALLATION; (16) FAILURE OF ELECTRICAL 

COMPONENTS DUE TO CONNECTION OF CHEMICAL DISPENSING EQUIPMENT INSTALLED BY OTHERS; (17) 

FAILURE OF FACILITY WATER HEATER TO MAKE TEMPERATURE; (18) FAILURE TO MAINTAIN WATER HARDNESS 

LOWER THAN 3.0 GRAINS, PH BETWEEN 7.0 AND 8.5 AND TOTAL DISSOLVED SOLIDS BELOW 250 PPM; (19) 

FAILURE TO COMPLY WITH LOCAL ELECTRICAL BUILDING CODES; (20) LEAKS OR DAMAGE RESULTING FROM 

SUCH LEAKS CAUSED BY THE INSTALLER, INCLUDING THOSE AT MACHINE TABLE CONNECTIONS, OR BY 

CONNECTION OF CHEMICAL DISPENSING EQUIPMENT INSTALLED BY OTHERS; (21) OPENING OR CLOSING OF 

UTILITY SUPPLY VALVES OR SWITCHING OF ELECTRICAL SUPPLY CURRENT; (22) PERFORMANCE OF REGULAR 

MAINTENANCE AND CLEANING AS OUTLINED IN THE OPERATOR’S GUIDE; (23) REMOVAL OR REINSTALLATION 

OF INACCESSIBLE DISHMACHINES OR BUILT-IN FIXTURES THAT INTERFERE WITH SERVICING, REMOVAL OR 

REPLACEMENT OF THE DISHMACHINE; (24) REPLACEMENT WEAR ITEMS INCLUDING, BUT NOT LIMITED TO, 

CURTAINS, DRAIN BALLS, DOOR GUIDES, GASKETS, O-RINGS, SEALS, SQUEEZE TUBES, AND BEARINGS; (25) 

RESIDENTIAL USE; (26) USE WITH UTILITY SERVICE OTHER THAN THAT DESIGNATED ON THE RATING PLATE.

Содержание Delta HT-E-SEER-S

Страница 1: ...DELTA HT E SEER INSTALLATION OPERATION AND SERVICE MANUAL Delta HT E SEER Manual 07610 004 54 86 D DELTA SERIES GLASSWASHER DISHMACHINES ...

Страница 2: ...talled by Jackson at the factory and are shipped with the Dishmachine carry only a 1 one year parts warranty Labor to repair or replace these components is not included in the warranty or covered by Jackson Booster heaters not manufactured by Jackson are not covered by this warranty but are warranted by their respective manufacturers This warranty is void if any defect or failure is a direct resul...

Страница 3: ...ROM DEFECTS IN MATERIALS AND WORKMANSHIP AND IS REPORTED TO JACKSON WITHIN 30 THIRTY DAYS FROM THE DATE OF INSTALLATION 9 DAMAGE CAUSED BY LABOR DISPUTE 10 DAMAGES RESULTING FROM IMPROPER CONNECTION TO UTILITY SERVICE 11 DAMAGES RESULTING FROM WATER CONDITIONS INADEQUATE OR EXCESSIVE WATER PRESSURE ACCIDENTS ALTERATIONS IMPROPER USE ABUSE HANDLING OVERLOADS TAMPERING IMPROPER INSTALLATION OR FAILU...

Страница 4: ...ons and fault codes to pgs 21 25 Updated pg 29 to show panel and membrane together Corrected P N of item 20 on pg 38 Updated pg 40 Updated SEER System pgs 47 48 Updated drain water tempering kit and added link to instructions on pg 51 Updated schematic C 4 24 19 JH QOF 19 553 Updated schematic D 6 17 20 JH 8664 8709 Revised Programming Chemical Feeder Pumps section Updated Chemical Feeder Pumps pa...

Страница 5: ...his manual before making a call to our technical support staff Please have this manual open when you call so that our staff can refer you if necessary to the proper page Technical support is not available on holidays Contact technical support toll free at 1 888 800 5672 Technical support is available for service personnel only NOMENCLATURE Delta HT E SEER T Tall Stand Glasswasher dishmachine high ...

Страница 6: ...ssure Regulator 7 Shock Absorber 7 Connecting the Drain Line 7 Plumbing Check 7 Electrical Power Connections 8 Voltage Check 8 Surrounding Area 8 Temperature Setpoints 8 Leveling 8 Chemical Connections 9 Priming Chemical Feeder Pumps 10 Programming Chemical Feeder Pumps 11 Operating Instructions 14 Preparation 14 Power Up 14 Filling the Wash Tub 14 Ware Preparation 15 Washing a Rack of Ware 15 Ope...

Страница 7: ... Block Box 30 Control Kick Panel 31 Electrical Panel 32 Chemical Feeder Pump Assembly 33 Door 35 Door Interlock 37 Miscellaneous Door Components 38 Wash Motor 39 Rinse Manifold 41 Plumbing 42 Rinse Plumbing 44 Scale Prevention System 46 Rinse Tank 47 SEER System 49 Tub Frame 51 Miscellaneous Parts 53 SCHEMATICS 208 230 V 50 60 Hz 1 Phase 54 ...

Страница 8: ...z ID Inside Diameter kW Kilowatts NFPA National Fire Protection Association NPT National Pipe Thread OD Outside Diameter PRV Pressure Regulating Valve PSI Pounds per Square Inch V Volts CAUTION WARNING NOTICE Risk of Injury to Personnel Risk of Damage to Equipment Risk of Electrical Shock Lockout Electrical Power Reference Data Plate Important Note i Caustic Chemicals Instructions Hyperlink ...

Страница 9: ...ue 1 2 ID line 40 90 F C Drain Connection 1 ID 1 3 8 OD Connect to MIN 1 1 2 Drain with Air gap D Chemical Port All dimensions from the floor can be increased 1 using the machine s adjustable feet 26 7 8 692 mm 1 4 7 mm 40 7 8 1037 mm 4 3 8 110 mm 12 304 mm CLEARANCE 3 76 mm 14 356 mm DOOR OPEN 24 1 4 615 mm Back and side views shown with back panel removed 3 5 8 91 mm 10 1 4 261 mm 8 1 2 216 mm 1...

Страница 10: ...h Air gap D Chemical Port All dimensions from the floor can be increased 1 using the machine s adjustable feet 3 76 mm 3 5 8 91 mm 10 1 4 261 mm 14 356 mm DOOR OPEN 24 1 4 615 mm 20 3 8 518mm 15 1 2 393 mm 13 3 4 349 mm 25 1 2 648 mm 41 3 4 1059 mm 27 3 8 695 mm 26 7 8 692 mm 1 4 7 mm 40 7 8 1037 mm 4 3 8 110 mm 12 304 mm CLEARANCE 13 1 4 337 mm 8 1 2 216 mm 15 7 8 402 mm Back and side views shown...

Страница 11: ...ratures F Minimum Wash Temperature 155 Minimum Rinse Temperature 180 Minimum Incoming Water Temperature 40 Maximum Incoming Water Temperature 90 Other Water Requirements Water Flow Pressure PSI 10 Flow Rate Minimum GPM 4 33 Water Line Size NPT 3 4 Male GHT Connect to true 1 2 ID Line Drain Line Size NPT 1 ID 1 3 8 OD Connect to MIN 1 1 2 Drain with Air gap Gallons per Hour GPH 13 Gallons per Rack ...

Страница 12: ...the machine data plate The electrical configurations are as follows Available Electrical Characteristics 208 V 60 Hz Single phase 230 V 60 Hz Single phase Available Wash Motors 1 HP Available Wash Tank Heaters 3 3 kW 208 V 4 kW 230 V Available Rinse Tank Heaters 4 1 kW 208 V 5 45 kW 230 V Delta HT E SEER Electrical Characteristics VOLTS 208 230 PHASE 1 1 FREQ 60 60 WASH MOTOR AMPS 5 0 A 5 0 A WASH...

Страница 13: ...esses can become lodged in the solenoid valves and prevent them from opening or closing Any valves that are found to be fouled or defective because of foreign matter left in the water line and any subsequent damage are not the responsibility of the manufacturer See the Dimensions page and reference item B for water inlet connection location The manufacturer does NOT endorse Tankless On demand wate...

Страница 14: ...uring the cycle A shock absober comes standard on the Delta HT E SEER This prevents water hammer or hydraulic shock induced by the solenoid valve as it operates from causing damage to the equipment The machine has a pumped pressure drain capable of pumping waste water to a height of 24 above the machine s drain pump and is supplied with a drain hose There must be an air gap between around the mach...

Страница 15: ...problems Replace the terminal block box cover and tighten down the screws This is a commercial machine and reaches temperatures that can exceed those generated by a residential machine Surrounding countertops cabinets flooring material and subflooring material must be designed and or selected with these higher temperatures in mind CAUTION Damage to materials not recommended for higher temperatures...

Страница 16: ...e port and into the wash chamber Chemical containers can be stored under the machine for the Delta HT E SEER T and nearby for the Delta HT E SEER S The bottoms of chemical containers cannot be located any higher than 14 from the floor Delta HT E SEER S Delta HT E SEER T CHEMICAL CONNECTIONS INSTRUCTIONS INSTALLATION CAUTION Using deionized water or other aggressive fluids will result in corrosion ...

Страница 17: ...ending on water quality and type of detergent 3 To prime the rinse aid pump press the II button and hold for one minute The amount of rinse aid might need to be adjusted depending on water hardness and results 4 Please refer to the next page for instructions on adjusting the amount of chemicals being dispensed PRIMING CHEMICAL FEEDER PUMPS 155 F READY RINSE AID PRIME WARNING Some of the chemicals ...

Страница 18: ...oth the MOVE and ENTER buttons simultaneously for two seconds then release PGM light will go steady and light A will start flashing 8 7 6 5 4 3 2 1 ON CHECK FUSE 1 2 3 4 5 6 7 8 ON 8 4 2 1 0 8 0 4 0 2 0 1 A B C D E F G H PGM ACCEPT MOVE ENTER IN SEC LIGHTS TIME BUTTONS CHECK FUSE 1 2 3 4 5 6 7 8 ON 8 4 2 1 0 8 0 4 0 2 0 1 A B C D E F G H PGM ACCEPT MOVE ENTER IN SEC LIGHTS TIME BUTTONS CHECK FUSE ...

Страница 19: ...is selected 1 2 3 4 5 6 7 8 ON 8 4 2 1 0 8 0 4 0 2 0 1 A B C D E F G H PGM ACCEPT MOVE ENTER IN SEC LIGHTS TIME BUTTONS CHECK FUSE 1 2 3 4 5 6 7 8 ON 8 4 2 1 0 8 0 4 0 2 0 1 A B C D E F G H PGM ACCEPT MOVE ENTER IN SEC LIGHTS TIME BUTTONS CHECK FUSE Light Steady Light Flashing Example here shows current setting for detergent dispensing time at 9 2 seconds each selected time option is added to get ...

Страница 20: ...bove To revert back to a previous setting repeat the process above and change parameters back to previous settings In programming mode if there have been no keypad inputs for approximately two minutes the system will automatically exit out of programming mode Any changes to parameters will be lost when programming mode is automatically exited 1 2 3 4 5 6 7 8 ON 8 4 2 1 0 8 0 4 0 2 0 1 A B C D E F ...

Страница 21: ...iously verified as correct If not the voltage must be verified before energizing the machine 1 Press the Power button 2 The machine will automatically begin the fill cycle 3 Once the wash tub is filled the machine displays HEATING 4 Wait for wash temperature to display at least 155 F and for the status to display READY before operating the machine OPERATING INSTRUCTIONS OPERATION PREPARATION POWER...

Страница 22: ...eans To do this ware must be properly prepared before being placed in the machine 1 Follow the Filling the Wash Tub section ensuring temperature is at least 155 F and the status displays READY 2 Open the door completely 3 Slide the rack into the machine 4 Close the door 5 Choose the cycle the default is cycle I WASHING A RACK OF WARE WARE PREPARATION OPERATING INSTRUCTIONS OPERATION 155 F READY CY...

Страница 23: ...e will automatically enter the venting cycle 10 After the venting cycle is complete the machine will automatically go back to being READY Open door and remove rack of ware To start another cycle load another rack of ware close door and push the Start button 155 F WASHING CYCLE 1 OPERATING INSTRUCTIONS OPERATION WASHING A RACK OF WARE 180 F RINSING 10 PSI Temperature shown is the minimum required t...

Страница 24: ...rush and flush with fresh water OPERATIONAL INSPECTION SHUTDOWN CLEANING OPERATING INSTRUCTIONS OPERATION Based on use the strainers might become clogged with soil and debris as the workday progresses Operators should regularly inspect the strainers to ensure they have not become clogged Clogged strainers will reduce the washing capability of the machine Instruct operators to clean out the straine...

Страница 25: ...ft strainer is free of debris 8 Spray or wipe out interior of machine 9 Replace wash and rinse arms 10 Replace the strainers and ensure they are laying flat 11 Use stainless steel polish to clean and protect outside of machine SHUTDOWN CLEANING OPERATING INSTRUCTIONS OPERATION Use a screwdriver to ensure end caps are tight ...

Страница 26: ...Follow the Filling the Wash Tub section of this manual 5 Open the door and add the amount of deliming solution recommended by the chemical supplier 6 Close the door and press the Delime button on the display The status will display DELIME 7 Press the Start button 8 The machine will delime drain and refill 9 Wait five minutes then inspect the machine If the machine is not delimed run again 10 When ...

Страница 27: ...ater will reduce this occurence Treated water might not be suitable for use in other areas of operation and it might be necessary to install a water treatment system for the water going to the machine only Discuss this option with a qualified water treatment specialist Properly train operators on how much detergent is to be used per cycle Meet with a water treatment specialist and chemical supplie...

Страница 28: ...ating PREVENTATIVE MAINTENANCE i XXXXXXXXX ATTENSION SE CONNECTER A UN MINIMUM D ALIMENTATION 30 AMPERES DELAI FUSIBLE DE TYPE NON TEMPS OU LA PROTECTION CONTRE LES SURINTENSITES NOTE WASH AND RINSE HEATER DO NOT OPERATE AT THE SAME TIME ELECTRICAL LOADS BASED ON WASH MOTOR AND RINSE HEATER HIGHEST AMP DRAW CAUTION IF THIS MACHINE IS CONNECTED TO A CIRCUIT PROTECTED BY FUSES U S E O N LY 3 0 A N O...

Страница 29: ...rations 8 Clean the machine at the end of every workday see Shutdown and Cleaning section 9 If hard water is present install an SPS into the water line connecting to the machine see the Water Supply Connections section 10 Always contact a qualified service agency whenever a serious problem arises 11 Follow all safety procedures whether listed in this manual or put forth by local state or national ...

Страница 30: ...cle The machine s program number must be correct to ensure the machine works properly To confirm the program number 1 Press and hold the I and III Buttons until Program flashes 2 3 seconds 2 Confirm bottom display shows 8 If not contact a qualified service agency 3 Press the Delime Button to exit PROGRAM PROGRAM 8 READY CYCLE 1 150 F ...

Страница 31: ...rough the categories will be flashing Language Wash Offset Temperature Scale Rinse Offset Wash Temperature Boost Offset Boost Temperature Spare Offset 4 Press the Select Button to choose the category you want to change Regardless of the category Steps 5 7 remain the same 5 Use the Up arrow Button to change the options will be flashing Numerical options are shown in the top window 6 Press the Selec...

Страница 32: ...Ω resistor for T3 and verify that booster heater turns off If not replace IO module 3 Verify that the booster probe resistance is correct with respect to temperature see table on pg 24 If not replace T3 F3 No water in wash tank Check inlet water and door 1 Malfunction of fill solenoid or fill relay 2 Door is open which inhibits fill mode 3 Faulty door switch 1 Replace faulty component 2 Close door...

Страница 33: ...t to temperature see table on pg 24 If not replace T1 F8 No water in wash tank Check inlet water and door 1 Malfunction of fill solenoid or fill relay 2 Door is open which inhibits fill mode 3 Faulty door switch 1 Replace faulty solenoid or fill relay 2 Close door to activate door switch 3 Replace or adjust door switch DISPLAY SHOWS POSSIBLE CAUSES REMEDY F9 Service needed Check incoming power 1 I...

Страница 34: ...n wire or unseated terminal by gently pulling on each wire at each end of the cable Reseat any loose terminals by inserting it fully into the housing using long nosed pliers Replace cable if broken wire is found 3 Temporarily substitute a verified good display board and check if F13 message recurs If so repeat substitution with a good I O module DISPLAY SHOWS POSSIBLE CAUSES REMEDY FAULT CODES TRO...

Страница 35: ...ter coming through the rinse assemblies 1 Limed up rinse heads or piping 2 Low water pressure 1 Delime rinse heads 2 Increase pipe size to machine Adjust pressure regulating valve Rinse water runs continuously with breaker turned off 1 Defective plunger in solenoid valve 2 Defective diaphragm in solenoid valve 1 Replace plunger 2 Replace diaphragm WARNING Inspection testing and repair of electrica...

Страница 36: ...efective drain valve 3 Defective wash pump 4 Defective motor contactor 5 Defective timer 1 Remove obstruction 2 Replace drain valve 3 Replace wash pump 4 Replace contactor 5 Replace timer Incorrect water pressure displayed during Fill or Rinse 1 Water turned off 2 Transducer disconnected 3 Pressure transducer defective 1 Turn water on 2 Verify wiring 3 Replace pressure transducer TROUBLESHOOTING T...

Страница 37: ... 004 36 47 1 Terminal Box Cover not shown 05700 003 27 70 3 1 Strain Relief 05975 003 37 56 4 1 Terminal Block Track 05700 000 43 60 5 2 Terminal Block 05940 500 02 19 6 2 Locknut 10 24 Hex with Nylon Insert 05310 373 01 00 7 1 Decal L1 N 09905 011 62 72 8 1 Ground Lug 05940 200 76 00 6 7 5 4 8 1 3 2 TERMINAL BLOCK BOX PARTS ...

Страница 38: ... 42 4 1 Bushing Snap 05975 210 09 00 5 4 Locknut 10 24 Hex with Nylon Insert 05310 373 01 00 6 1 Cover Display 05700 004 52 43 7 4 Nut Thumb 6 32 Nylon 05310 002 83 12 8 1 PCB Digital Display 05945 004 46 18 9 4 Spacer Unthreaded 9 32 Nylon 05975 004 47 89 10 1 Panel Membrane Switch Assembly 05700 004 68 71 11 1 Communication Cable 05700 004 33 64 11 Complete Control Kick Panel Assembly 05700 004 ...

Страница 39: ...al Board 05940 004 21 34 5 1 Terminal Board 05940 002 78 97 6 3 Contactor 30 A 240 V 05945 002 74 20 7 2 Relay 05945 111 89 75 8 1 Dinrail 2 05700 002 36 09 9 1 Timer Universal Digital 05945 004 22 78 10 1 Electrical Panel 05700 004 52 15 11 4 Screw 6 32 x 3 8 05305 002 25 91 12 15 Screw 10 32 x 5 8 05305 003 02 12 13 3 Screw 10 32 x 1 05305 002 19 42 Complete Electrical Panel Assembly 05700 004 5...

Страница 40: ...33 07610 004 54 86 D 24 PARTS CHEMICAL FEEDER PUMP ASSEMBLY 18 Complete Chemical Feeder Pump Assembly 05700 004 52 18 19 23 22 21 20 ...

Страница 41: ... 10 10 1 Complete Peri pump Assembly 36 RPM Motor Only Peri pump 36 RPM 05700 004 71 53 04320 111 47 47 11 1 Tube 8 05700 003 22 89 12 1 Roller Red Plastic 04320 111 36 70 13 1 Timer Universal 05945 003 75 23 14 4 P clamp 1 4 ID 05975 002 61 42 15 4 Locknut 10 24 Hex with Nylon Insert 05310 373 01 00 16 1 Panel Outer Control 05700 004 52 16 17 3 Screw 10 32 x 1 05305 002 19 42 18 2 Stiffener Chemi...

Страница 42: ...35 07610 004 54 86 D DOOR PARTS Complete Door Assembly 05700 004 54 05 ...

Страница 43: ...1 44 37 10 1 Door Handle 05700 003 26 62 11 2 Bolt 1 4 20 x 3 8 Hex 05305 274 20 00 12 2 Screw 10 32 x 1 4 05305 173 01 00 13 1 Switch Assembly 05700 003 34 80 14 1 Washer 1 4 20 ID 05311 174 01 00 15 1 Gasket Door 20 05330 003 58 35 16 2 Gasket Door 14 1 2 05700 004 54 09 17 1 Channel Door Seal 05700 004 54 11 18 6 Screw 1 4 20 x 1 1 2 Hex Head 05305 274 23 00 19 1 Gasket Door L 05330 004 36 05 2...

Страница 44: ...th Nylon Insert 05310 374 02 00 5 1 Bracket Solenoid 05700 004 50 99 6 1 Bracket Solenoid Guide 05700 004 51 00 7 4 Screw 6 32 x 1 8 Pan Head Phillips 05305 004 51 01 8 1 Spring Conical Compression 05340 004 47 53 9 1 Guide Plate Door Interlock 05700 004 47 40 Item not included in complete door interlock assembly and must be ordered separately 7 DOOR INTERLOCK PARTS 7 Complete Door Interlock Assem...

Страница 45: ...nting Plate Assembly 05700 003 33 54 2 2 O ring 05330 003 32 34 3 1 Latch Spring 05340 004 67 82 4 2 Latch Nut 05700 003 32 33 5 2 2 Locknut 6 32 Hex with Nylon Insert Screw 6 32 x 1 4 05310 373 03 00 05305 171 01 00 6 1 Door Switch 05930 003 31 44 7 1 1 Door Switch Bracket Door Switch Bracket Assembly 05700 003 31 43 05700 003 32 21 8 1 Switch Mount Assembly 06401 004 47 76 ...

Страница 46: ...39 07610 004 54 86 D WASH MOTOR PARTS 3 4 5 5 6 5 1 5 5 15 18 8 9 15 15 14 2 10 17 15 11 15 16 16 13 12 13 19 20 15 7 15 ...

Страница 47: ...h Hub 05330 002 34 77 9 1 Wash Hub 05700 004 43 04 10 1 Pump and Motor 06105 004 50 75 11 1 Hose 7 8 ID x 8 Blue Silicone 05700 004 43 76 12 1 Hose Bottom Manifold Pump 05700 001 22 92 13 2 Clamp 1 1 16 to 2 04730 719 18 00 14 1 Hose 1 1 4 ID x 4 Blue Silicone 05700 004 54 00 15 7 Clamp 13 16 to 1 1 2 04730 719 06 09 16 2 Hosebarb 1 3 4 04730 011 65 86 17 1 Drain Valve Assembly 04730 003 33 64 18 ...

Страница 48: ...00 35 06 3 4 Rinse Arm End cap 04730 111 60 41 4 2 Complete Rinse Arm Assembly 05700 004 39 39 2 Rinse Arm 05700 004 38 75 5 2 Bearing Assembly Rinse Arm 05700 004 54 71 6 2 O ring included in item 5 05330 002 60 69 7 2 Retaining Ring 05340 112 01 11 RINSE MANIFOLD PARTS 1 2 3 4 3 3 3 4 Rinse Arm Bearing Kit 06401 004 57 50 5 7 6 ...

Страница 49: ...07610 004 54 86 D 42 PLUMBING PARTS Complete SEER Plumbing Assembly 05700 004 63 78 3 9 8 7 6 4 5 2 1 10 CONNECTS TO HOT WATER OUTLET ON SEER SYSTEM CONNECTS TO COLD WATER INLET ON SEER SYSTEM ...

Страница 50: ... 3 1 Booster Tank Discharge Assembly 05700 004 55 97 4 1 Tee 1 2 Brass 04730 211 27 00 5 1 Nipple 1 2 Close Brass 04730 207 15 00 6 1 Water Hammer Arrestor 1 2 04730 004 58 56 7 1 SEER Inlet Plumbing Assembly 05700 004 60 46 8 1 Elbow 90 degree 1 2 Street Brass 04730 206 08 00 9 1 Adapter Double Male 3 4 11 5 x 1 2 14 04720 004 51 55 10 1 Inlet Hose Assembly 05700 004 71 03 ...

Страница 51: ...07610 004 54 86 D 44 RINSE PLUMBING PARTS 1 2 3 2a 2d 2e 2h 2f 2g 2c 2b ...

Страница 52: ... 2c 2d 2e 2f 2g 2h 1 1 1 2 1 1 1 2 1 Complete Rinse Injector Assembly Rinse Injector Only Gasket Rinse Injector Screw 1 4 20 x 1 Check Valve Fitting Outlet Elbow Nut Tube 1 8 Plug 1 8 Brass Pressure Transducer 05700 004 43 86 09515 004 22 73 05330 003 75 91 05305 011 81 58 04820 111 51 14 04820 111 51 18 04730 011 59 45 04730 209 07 37 05945 004 17 01 3 1 Harness Transducer 05700 004 33 62 ...

Страница 53: ...04 SPS 04730 003 28 03 Replacement Test Strip Not Shown 06401 003 28 06 Must be installed vertically The provided bracket is secured to the wall Observe proper inlet outlet water directions flow directions are molded into the top of the head Line pressure should be released before changing cartridges Machine should be delimed before installation NOTICE ...

Страница 54: ...47 07610 004 54 86 D RINSE TANK PARTS 1 2 3 4 5 Front of Rinse Tank 6 7 8 Back of Rinse Tank 9 ...

Страница 55: ...04540 004 45 12 4 4 Lockwasher Split 5 16 05311 275 01 00 5 4 Nut Hex 5 16 18 05310 275 01 00 6 1 Cable Temperature Probe 05700 004 33 23 7 1 Thermistor Probe 4 with 18 Cable 06685 004 34 58 8 1 Fitting 1 4 Brass Nut Sleeve 05310 924 02 05 9 1 Plug 1 4 Brass 04730 209 01 00 10 1 Thermostat Rinse Tank High limit Not Shown 05930 004 33 12 RINSE TANK PARTS ...

Страница 56: ...49 07610 004 54 86 D SEER SYSTEM PARTS 5 4 3 14 2 6 5 1 13 7 8 11 9 12 10 12 15 16 17 18 Complete SEER System Assembly 05700 004 63 06 Before ordering SEER System parts see note on the next page NOTICE ...

Страница 57: ...iller Plate 05700 004 58 93 9 1 Diversion Plate 05700 004 59 04 10 1 Upper Shield 05700 004 58 98 11 1 Heat Exchanger 3 8 Tubes 04420 004 58 96 12 12 Locknut 1 4 20 Hex with Nylon Insert 05310 374 01 00 13 8 Screw 6 32 x 1 2 05305 004 23 63 14 1 Condenser Assembly 05700 004 58 94 15 2 Bolt 1 4 20 x 1 2 05305 274 02 00 16 1 Plumbing SEER Inlet 05700 004 60 46 17 1 Bracket Bearing Hard Stop 05700 00...

Страница 58: ...51 07610 004 54 86 D TUB FRAME PARTS 1 2 4 3 6 5 26 27 25 7 8 9 10 11 12 22 23 24 19 21 20 FRONT BACK DETAIL A 16 17 18 15 14 13 28 ...

Страница 59: ...Thermostat High limit 05930 004 33 12 15 1 Thermostat High limit 05930 004 33 15 16 2 Fitting Brass Sleeve 05310 924 02 05 17 1 Thermistor Probe 4 with 18 Cable 06685 004 34 58 18 1 1 Wash Heater 4 kW Gasket Wash Heater Not Shown 04540 003 99 44 05330 011 61 34 19 1 Bracket Terminal Box 05700 004 55 90 20 1 Bracket Rinse Tank Plumbing Support 05700 004 56 19 21 1 Fitting Bulkhead to 1 2 Hosebarb 0...

Страница 60: ... 1 Rail Left Rack 05700 031 37 88 2 1 Rail Right Rack 05700 031 37 88 3 1 Splash Shield 05700 003 33 51 4 1 Dual Float Switch 06680 004 48 53 5 1 Drain Water Tempering Kit 06401 004 59 11 Parts are not shown to scale in relation to each other 4 Drain Water Tempering Kit Install Instructions ...

Страница 61: ...1 L2 N Input Assignments I1 Wash I2 Cycle I3 Float I4 Rinse I5 Door Chemicals BLK DC RTN RED 24 VDC WHT BLK DC RTN VDC OUT CORRESPONDING CONNECTOR TO DISPLAY PCB PN 05945 004 36 33 B L K B L K R E D W H T B L K G R N LOGIC INPUT VDC OUT T3 GRN BLK K 2 K 3 K 4 K 5 K 6 K 7 K 8 K 9 K 10 K 11 K 12 Interconnect cable is Belden 9745 060U500 3 twisted pairs Connection Diagram for IO Module DC RTN 1 2 3 4...

Страница 62: ...Jackson WWS Inc 6209 N US Hwy 25E Gray KY 40734 USA 1 888 800 5672 www jacksonwws com Delta HT E SEER Manual 07610 004 54 86 D ...

Отзывы: