07610-002-10-23-V
21
DELIME NORMAL
1.
Flip “OFF/ON/FILL” switch to “ON” position.
2.
Close door and hold “OFF/ON/FILL” switch in “FILL “ position for
approximately
8-10 seconds.
3.
Water must be between two lines on drain stopper.
4.
Add deliming solution per chemical supplier’s instructions.
5. Close door.
6.
Flip NORMAL/DELIME switch on back of control box to DELIME.
7. Run machine period of time recommended by chemical supplier.
8.
Wait five minutes, then inspect inside of machine. If machine is not
delimed, run
again.
9.
Flip NORMAL/DELIME switch to NORMAL.
10. Run two cycles to remove residual deliming solution.
11.
Drain and re-fill machine.
CAUTION!
This equipment is not recommended for use with deionized water or
other aggressive fluids. Use of deionized water or other aggressive fluids will result
in corrosion and failure of materials and components. Use of deionized water or
other aggressive fluids will void the manufacturer’s warranty.
OPERATING INSTRUCTIONS
OPERATION
DELIMING
!
CAUTION
Содержание CONSERVER XL2C
Страница 38: ...07610 002 10 23 V 31 HOOD ASSEMBLY PARTS 1 6 7 4 2 5 3 9 8 2 3 2 10 11 6 7 8 9 2 12 13 2 14 7 9 8 6 15 10 2...
Страница 49: ...07610 002 10 23 V 42 WASH MANIFOLD ASSEMBLY PARTS 1 7 4 5 2 6 9 3 8 10 11 12 13...
Страница 52: ...07610 002 10 23 V 45 SCHEMATICS XL2 CML CMR 115 V 60 HZ 1 PHASE...
Страница 53: ...07610 002 10 23 V 46 SCHEMATICS XL2 CML CMR 208 230 V 50 60 HZ 1 PHASE...