Revised: N/A
SEAL, CRANE
BEARINGS (2 REQ.)
RING, RETAINER
SHAFT
WASHER, PHENOLIC
HOUSING, PUMP
PUMP HOUSING GASKET
ROTATION
IMPELLER
INSTALLING NEW SEAL IN WASH PUMP
1. Remove the four bolts holding pump to the machine.
2. Hold shaft and rotate impeller counterclockwise to unscrew and remove. Be careful not to damage shaft.
3. Remove the three screws holding retainer ring to the pump housing.
4. Press out shaft and bearings by pushing against threaded end of the shaft.
5. Press crane seal out of pump housing.
6. Install new seal using Permatex # 1 around housing where seal fits.
7. If surface on impeller where seal rubs is cored, either reface or install new impeller.
8. Examine bearings and if they seem rough, replace.
9. Reassemble pump being certain that drip hole in housing is facing down when assembling to machine.
Содержание 10AB-N70
Страница 8: ...Revision Letter Revision Date Made By Applicable ECNs Details...
Страница 59: ...APPENDIX A DEMA Nitro Warewash Dispenser A 1...
Страница 61: ...Part 1 Nitro Warewash Dispenser User s Manual...
Страница 70: ...Part 2 Solid Rinse Bowl Installation Instructions...
Страница 75: ...Part 3 Viking Bowl Installation Instructions...
Страница 78: ...Part 4 Nitro Warewash Dispenser Training Manual...
Страница 113: ...Enter New Code Access Code gains access to system programming setup Press ENTER to modify access code...
Страница 115: ...Accept Program Code Press EXIT to accept new access code Press any other button to reject new access code...
Страница 116: ...Press EXIT to leave programming mode or use UP DOWN arrows to navigate to other screens to make changes...