background image

  

This will allow the orifices to disengage 
from the burner venturi. 

 
6.

 

Unscrew each gas valve and re-install 
new natural gas valves and orifices.  
Use teflon tape or pipe dope when 
installing valves and orifices. 

 

G

AS 

L

INE 

 
Remove the 3/8” flare fitting that attaches 
the propane hose from the fitting block 
inside of the pedestal and replace with an 
approved 10’ neopream hose. 
 
Make sure when the new gas valves are 
installed that they have a bright silver 
face near the stem of the gas valve.  This 
identifies them as Natural Gas valves.  

REMEMBER TO LEAK CHECK ALL 
FITTINGS.  AFTER ALL OF THE 
CONVERSION IS COMPLETED, LEAK 
CHECK ALL FITTINGS AND TEST FIRE 
ALL BURNERS TO ENSURE PROPER, 
SAFE OPERATION. 
 

MAINTENANCE

 

 
Burner Inspection 
 

We recommend that the gas burners be 
inspected and cleaned once a year. 

 

B

urner 

R

emoval for 

C

leaning 

 
1.

 

Ensure the gas supply is off and grill is 
cool. 

2.

 

Remove cooking grates and flame 
tamers. 

3.

 

Remove burner mounting screw 
located at the very back of burner near 
the rear of the firebox. 

4.

 

Remove burners by lifting up and out 
of firebox on an angle.  Repeat for all 
burners. 

5.

 

Clean the outside of the burners with a 
wire brush and make sure all gas ports 
are clear.  Use a straight coat hanger 
to clear any obstructions. 

 
6.

 

Use a flashlight to look into the venturi 
end of the burner to check for 
blockages.  If necessary, use a straight 
coat hanger to clear any obstructions. 

 
7.

 

Inspect and clean the venturi end of 
the burner by removing the venturi set 
screw on the end of the burner and 
removing the venturi shutter.  Once 
removed, make sure the burner is 
thoroughly cleaned and the venturi 
shutter is re-installed with an opening 
of 1/8” for Natural Gas and ¼” for 
Propane. 

 
8.

 

Re-install and secure burner. 

 
9.

 

Re-mount flame tamers and cooking 
grids. 

 
10.

 

Light each burner to ensure they are 
operating correctly. 

 

Note:  

When installing burners, it is 

very

 

important to center the burner over the 
gas orifice.  You should look under the 
main control panel with a flashlight once 
installed  to  make  sure  they  are  in  the 
proper position.  Failure to clean and 
install burners correctly could result in fire 
or explosion. 
 

H

ELPFUL 

H

INTS FOR 

C

LEANING THE 

C

OOKING 

G

RILLS

 

 
Do not clean the cooking surface once the 
grill has cooled down.  Allow cooking 
residues to remain on the surface until the 
next time you grill, then do a pre-burn for 
10 minutes prior to grilling.  Remove 

Содержание JG3

Страница 1: ...xplosion Homeowners should retain these instructions C CO ON NT TE EN NT TS S A Message to our Customers 2 Safety 3 Installation 3 Clearances 4 LP Gas Cylinder 4 Specifications 4 OPD Equipped Cylinder 6 Hose and Regulator 6 Leak Testing 8 Gas Conversion 8 Maintenance 9 Lighting Instructions 11 Trouble Shooting 12 Warranty 13 Proudly Manufactured By Jackson Grills Inc G2 4970 Polkey Rd Phone 1 250 ...

Страница 2: ...ue for quick reference If you need to obtain replacement parts for your Jackson Grill contact your local dealer NOTE It is normal for stainless steel surfaces to discolor due to high heat given off from the barbeque burners Please take the time to fill out and return the Ownership and Registration Card below It can be mailed to Jackson Grills Inc G2 4970 Polkey Road Duncan B C V9L 6W3 or fax 1 250...

Страница 3: ...er appliance CAUTION 1 For outdoor use only 2 If stored indoors detach and leave cylinder outdoors 3 This appliance must not be operated unattended 4 Special care must be taken to keep small children away from heated surfaces ELECTRICAL CAUTION 1 If any accessory is used on this appliance with an external electrical power source the accessory when installed must be electrically grounded in accorda...

Страница 4: ...upling Your grill is designed to be used with an LP gas cylinder equipped with the new QCC 1 Quick Closing Coupling system The QCC 1 system incorporates new safety features required by the Canadian Standards Steering Committee and the American National Standards Institute ANSI Gas will not flow until a positive connection has been made A thermal element will shut off flow of gas between 240 degree...

Страница 5: ...ons prohibit shipping full LP gas cylinders You must take your new cylinder to an LP gas dealer for filling 2 A filled LP gas cylinder is under very high pressure Always handle with care and transport in the upright position Protect the valve from accidental damage 3 Do not tip the LP gas cylinder while connecting it to the regulator Fasten the cylinder securely during transport use and storage 4 ...

Страница 6: ...harges of raw propane The new OPD causes a slower purge fill operation Some consumers have been advised by filling stations that these cylinders are defective This is not a defect Some propane filling stations may not be aware of this new device and its effects on the purge fill operation IDENTIFICATION To identify these cylinders the new OPD handwheel has been standardized to the shape shown HOSE...

Страница 7: ...other hand turn the hand wheel clockwise until there is a positive stop Do not use tools Hand tighten only When making the connection hold the regulator in a straight line with the cylinder valve so as not to cross thread the connection 4 Leak test the connection See leak test 5 Refer to lighting instructions To avoid activating the Flow Limiting Device when lighting open the cylinder valve slowly...

Страница 8: ...e appliance until the leak s is corrected NATURAL GAS INSTALLATIONS The outdoor cooking gas appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa The outdoor cooking gas appliance must be isolated from the gas supply by closing its individual manual shut off valve duri...

Страница 9: ...all burners 5 Clean the outside of the burners with a wire brush and make sure all gas ports are clear Use a straight coat hanger to clear any obstructions 6 Use a flashlight to look into the venturi end of the burner to check for blockages If necessary use a straight coat hanger to clear any obstructions 7 Inspect and clean the venturi end of the burner by removing the venturi set screw on the en...

Страница 10: ... and the flame tamers that are over each burner 2 Turn the burner you are lighting to high light and place a long match near the side gas ports of the burner 3 If the burner does not immediately light turn the valve to OFF Wait 5 minutes then repeat lighting procedures REAR BURNER LIGHTING If equipped 1 Light the rear burner by placing a long match next to the gas ports on the rear burner then tur...

Страница 11: ...rner control to high position Remove warming rack Depress Igniter button and hold or light with a match Turn rear burner control to high positionand light with a match If ignition is not immediate turn burner control off Wait 5 minutes If ignition is not immediate turn burner control off Wait 5 minutes With left burner operating on high turn the center and or right burner to high ...

Страница 12: ...essive great on sear plates and in drip pan Clean flame tamers and drip pan regularly Do not line pan with aluminum foil Refer to cleaning instructions Burners burn with yellow flame accompanied by smell of gas Possible spider web or other debris Thoroughly clean burner by removing See maintenance instructions Burner will not light with ignitor but will light with match Dead battery in ignitor Cha...

Отзывы: