background image

 

Plasma 40i 

Operating manual 

Page 25 

28.  Ersatzteile / spare parts IP44 

 
 

 

Frontansicht / frontview 

 
 

Pos. 

Bezeichnung 

Designation 

Nummer 

number 

 

 

 

 

Rohrrahmen Pl25/40 IP44 

Pipe frame Pl25/40 IP44 

715.021.240 

Haube Plasma 25/40 IP44 

Case top Plasma 25/40 IP44 

715.021.215 

Frontfolie Plasma 40i 

Front label Plasma 40i 

304.021.105 

Kabelverschraubung M20x1,5 

Screwed cable gland M20x1,5 

420.700.001 

 

Gegenmutter M20x1,5 

Nut M20x1,5 

420.700.002 

Seitenblech Pl 25/40 IP44 

Side panel Pl25/40 IP44 

715.021.216 

Schutzgitter vorne PL25/40 IP44 

Protection grid front  Pl25/40 IP44 

715.021.210 

Massekabel Plasma - 10mm² 

Work piece cable - 10mm² 

702.100.001 

Seitenblech Pl 25/40 IP44 

Side panel Pl25/40 IP44 

715.021.216 

Kabelverschraubung M25x1,5 

Screwed cable gland M25x1,5 

420.025.001 

 

Gegenmutter M25x1,5 

Nut M25x1,5 

420.025.002 

10 

Schalengleiter X18 

Protective slider X18 

310.018.047 

11 

Brenner PJ45K komplett 

Torch PJ45K complete 

 

 

 

Содержание PJ 45k

Страница 1: ...Plasma 40i IP23 Plasma 40i IP44 mit Handbrenner PJ 45K with Hand torch PJ 45k Deutsch Seite 1 10 22 29 English Page 11 29...

Страница 2: ...ction of arc welding equipment in use Achtung Schutzart IP23 zur Verwendung im Innenbereich oder bei 100 Trockenheit im Au enbereich Schutzart IP44 zur Verwendung im Innenbereich und bei Regen im Au e...

Страница 3: ...elektromagnetische Probleme in der Umgebung bewerten und ber cksichtigen Gew hrleistung INFORMATION Unsachgem e Reparatur oder Wartung technische Ver nderung des Produktes eigenm chtige nicht ausdr ck...

Страница 4: ...den universellen Einsatz zum Handschneiden bestens geeignet Die folgenden Eigenschaften kennzeichnen die Funktionsweise Die feingefilterte druckgeregelte Luft verzweigt sich im Plasmabrennerk rper und...

Страница 5: ...cher Gef hrdung Herstellung gem Euronorm EN 60 974 1 EN 60 974 7 und EN 60 974 10 Generatorbetrieb Der Generator muss mindestens 30 mehr Leistung erzeugen als die maximale Leistung des Ger tes Beispie...

Страница 6: ...alien entfernen Abstand mindestens 10 m Hei e Metallteile und Schmelze abk hlen lassen Entflammbare Bereiche zuerst entl ften Keine Beh lter schneiden die brennbare Materialien enthalten auch keine Re...

Страница 7: ...he arbeitende Personen sind ebenfalls vor der Lichtbogenstrahlung zu sch tzen mobile Trennwand Vorhang etc 4 Schutz vor L rm Beim Gebrauch des Schneidger tes entsteht gro er L rm der auf Dauer das Ge...

Страница 8: ...aschinen von einem Arzt beraten lassen Achtung Es ist m glich dass im Bereich eines Krankenhauses oder hnlichem durch den Betrieb der Anlage elektromedizinische informationstechnische oder auch andere...

Страница 9: ...en oder Schneidstrom aktiv ist 6 Vorbereitung zum Schneiden Brenner ausr sten Geeignete Plasmad se entsprechend des eingestellten Schneidstroms in den Brenner montieren Eine zu gro e D senbohrung verr...

Страница 10: ...s Werkst ck so entsteht der Schneidlichtbogen Kommt der Schneidlichtbogen nicht zustande so wird der Pilotlichtbogen nach ca 4 Sekunden abgeschaltet Das Z nden des Pilotlichtbogens ohne damit zu schne...

Страница 11: ...es weiteren ist der Brenner bauartbedingt nicht wasserdicht so das dieser ebenfalls nicht mit stehendem Wasser ber hrt werden darf Plasmaschneiden wird mittels hoher Spannung und Strom durchgef hrt Da...

Страница 12: ...Netzkabel unterbrochen Netzkabel pr fen Beim Dr cken des Brennertasters keine Funktion vorhanden Brennerteile am Brennerkopf unvollst ndig montiert Brennerkopf berpr fen Sicherheitsschaltung Brennert...

Страница 13: ...Plasma 40i Operating manual Page 11 Operating manual Plasma 40i...

Страница 14: ...ble electromagnetic problems in the neighbourhood Warranty INFORMATION Improper repair or servicing technical modifications of the product unauthorized not strictly from J CKLE GmbH permitted modifica...

Страница 15: ...also for harder assembly work Requisites like the torch hose pack and other lines in use may be suspended on the tubular frame Its Operating principle is characterized by the following Compressed air...

Страница 16: ...IP44 Authorized for welding under increased electrical hazard Manufactured in accordance with EN 60 974 1 EN 60 974 7 and EN 60 974 10 Generator operation The generator must have 30 more power as the...

Страница 17: ...rried out by qualified electricians c Always disconnect mains prior to servicing maintenance and repair work and before opening the casing d Keep the machine always in good conditions e Modifications...

Страница 18: ...cases ventilation e g fan may be sufficient but usually an extraction system is necessary where harmful substances are produced 5 Danger from shielding gas cylinder Shielding gas cylinders contain pre...

Страница 19: ...omagnetic Compatibility Standards for cutting Systems EN 60 974 10 Electromagnetic compatibility EMC Safety inspection The owner operator is obliged to have a safety inspection performed on the machin...

Страница 20: ...cording to manufacturer s instructions respectively the at the main switch or step switch given data into the torch If the hole of the nozzle is too big the power and quality of the cut decreases If i...

Страница 21: ...ted and at the instant of the pilot arc impacting the work piece the cutting arc is formed In the event of a cutting arc failure the pilot arc is switched off after approx 4 sec Repeated ignition of t...

Страница 22: ...must never be placed in standing water or similar Further the torch is not designed to work waterproof so he also should not be touched with standing water Plasma cutting is performed by means of high...

Страница 23: ...mbly of torch head elements safety cut out Check torch head torch trigger defective Check torch trigger torch Control line interruption Check torch Control line fault indicators LEDS are lit see Chapt...

Страница 24: ...ner siehe Nr 29 Torch look Nr 29 5 Gurthalteblech Plasma 25ci Transport sheet Plasma 25ci 715 021 105 6 Haube Plasma 25 40 IP23 Case top Plasma 25 40 IP23 715 021 103 7 Geh use Plasma 40 IP23 Housing...

Страница 25: ...Plasma 40i Operating manual Page 23 Seitenansichten sideview IP23...

Страница 26: ...latine Pl40i Control pcb Pl40i 600 021 009 25 Brenneranschlu leiste Pl40i Torch terminal block Pl40i 418 063 040 26 Druckschalter Pl40i Pressure switch Pl40i 521 003 007 27 Hauptschalter beleuchtet Ma...

Страница 27: ...ble gland M20x1 5 420 700 001 Gegenmutter M20x1 5 Nut M20x1 5 420 700 002 5 Seitenblech Pl 25 40 IP44 Side panel Pl25 40 IP44 715 021 216 6 Schutzgitter vorne PL25 40 IP44 Protection grid front Pl25 4...

Страница 28: ...Plasma 40i Operating manual Page 26 Seitenansichten sideview...

Страница 29: ...Control pcb Pl40i 600 021 009 25 Brenneranschlu leiste Pl40i Torch terminal block Pl40i 418 063 040 26 Druckschalter Pl40i Pressure switch Pl40i 521 003 007 27 Hauptplatine mit Block komplett Main pcb...

Страница 30: ...rallring Swirl ring Nr 748 0034 10 D se Nozzle 0 65mm Nr 748 0035 10 D se Nozzle 0 80mm Nr 748 0049 10 D se lang Nozzle long 0 90mm Nr 748 0042 2 Schutzkappe protection cap Nr 748 0050 5 Distanzfeder...

Страница 31: ...Gg RP1 Nr Nr L2 DC Nr DC Rs OUT SP TA TP GV GV RP2 Chassis DYJC Rs L 230Vac 10 P1ph 50 60Hz Bc SOURCE TIP HFPOUT MB Bc Rs Bc Bc HF QF 2 3 LT SF LA LP LU Led1 Led2 Led3 Led4 EVG Nr Bc DRIVE SIGNAL SOU...

Страница 32: ...ngen vorbehalten Contents corresponding to technical standard at printing Errors and subjects to change without notice excepted 05 09 online www jaeckle sst de copyrightJ CKLE GmbH Bad Waldsee Germany...