Installation manual: OASiS security system JA-82KRC   

18 / 21 

MKH51100_OS2

 

12.45.  Go to maintenance mode 

By entering 

292

 while in Service Mode the system switches to 

maintenance mode. In maintenance mode it is possible to 
program the devices to be bypassed and to adjust the control 
panel internal clock (see 13.4).  

 

12.46.  Setting the internal clock 

 

The control panel has a built in real-time clock which is used to 

time-stamp all recorded events in the control panel memory. 
Adjust the clock after installation by entering:  

4 hh mm DD MM YY 

where:  

hh

  

is the time in hours (00 to 23) 

mm

  

is the time in minutes (00 to 59) 

DD

 

is the day (01 to 31) 

MM

  

is the month (01 to 12) 

YY

  

is the year (00 to 99) 

 

Note

: The internal clock can also be adjusted in maintenance mode.  

Example: On 30 June 2012 at 17:15 enter: 4 17 15 30 06 12 

 

After the control panel is powered up, the clock is set to  00 00 
01 01 00. 

12.47.  Editing keypad text   

The names of devices and programmable outputs as displayed 

on the keypad unit can be edited as follows:  

  Pressing and holding the 

?

 key (in service mode) enters text 

editing mode and the name of the device enrolled to address 
01 is then displayed with a flashing cursor on the first text 
character. 

 Key 

functions: 

 and 

  text scrolling (see table)  

1

 and 

7  

character-selection (A,B,C,D.......8,9,0) 

4

 and 

5  

cursor control (left/right) 

2

 

  delete selected character 

 

exit editing (& save changes) 

 

List of editable text: 

text  

Description 

01: to 50: Devices 

Names of devices in addresses 01 to 50 

Control panel 

Name of control panel (e.g. displayed if its cover 
is opened) 

Keypad 

Name of hard-wired keypad 

Communicator 

Name of the communicator in the control panel 

Master code 

Name of the master code 

01: to 50: Code 

Names of user codes  

ARC Code 

Names of ARC code 

Service code 

Name of the service code 

PGX  and PGY 

Names of programmable outputs 

OASIS JA-82 

The default text displayed in operating mode if 
no other text needs to be displayed. If erased 
then nothing will be displayed. 

 

Notes: 

  Only capital letters can be entered. 

  The length of text is limited to the length of the display. 

  The text is only stored in the keypad used for editing (different 

keypads in the system can show different text if desired). 

  Text is stored in the non-volatile memory of keypads, so power 

disconnection will not erase any stored text. 

  Convenient text editing is possible using a PC running OLink 

software. 

  Besides device names, keypads also use so-called internal text such 

as “service”, “maintenance mode” etc, and this text can also be 
edited via OLink software by selecting “Settings” on the menu and 
then “keypad text”.  

  After editing keypad text using OLink software, all keypads (including 

wireless ones) must be connected to the digital bus to save the 
changes to the keypad units by clicking on the OK button in the 
software. 

 

Factory default setting: in addresses 01 to 50 there is the text 
“Device”. Other default text: “Control panel”, “Keypad”, 
“Communicator”, “Master code”, users 01 to 50 “Code”,”ARC 
Code”, “Service code”, “PGX”, “PGY” and “OASIS JA-82”. 

 

13. Operating the system 

 

The Oasis system can be operated locally using a keypad or a 

keyfob and it can also be operated remotely by mobile phone or 
the Internet (if equipped with a suitable communicator). 

13.1. The 

system 

keypad 

Indoor keypads model JA-80F (wireless) or JA-80E (wired) can 

be used to operate and program the system. Both keypad types 
provide the same functionality: 

 

 

13.1.1. Keypad 

indicators: 

ABC  setting (arming) status of sections 

– if all sections are 

set then all these indicators (A B & C) are lit. 

 

 

Flashing = 

alarm, 

with the simultaneous 

display of alarm details on the LCD, 
e.g.:  

  

Alarm 

 

 03: 

Kitchen

 

Constantly lit  =

 

fault

 – details are displayed by 

pressing the “

?

” key 

 

Power

. Constantly lit = mains ok. Flashing = no 

mains, control panel powered by back-up battery 
only.  

 

13.1.2. LCD 

display 

The 1

st

 line displays the status: 

triggered detector, Service 

mode etc. In standby mode, it shows the text “OASIS JA-80” 
(editable, see 12.47). 

The 2

nd

 line displays the name of a device.

(e.g. 01: Main 

Door etc.). The text can be edited, see 12.47. 

 

Displaying the status of detectors and programmable 
outputs:

  Details on permanently triggered detectors (e.g. open 

windows) and the status of the PGX and PGY outputs can be 
displayed by pressing the 

key. 

13.1.3. Keypad 

display 

sleep-mode 

In operating mode, the wireless keypad unit displays the 

system status for 20 seconds (if battery-powered)  after the last 
interaction with a user, and then goes into sleep mode. Pressing 
any key, triggering the keypad input or opening the keypad’s flip 
cover re-activates the display.  

 

13.1.4. Keys 

0–9

 

digital code entry 

  

function sequences 

#

  

escape 

Содержание OASiS JA-82KRC

Страница 1: ...nual OASiS security system JA 82KRC 1 21 MKH51100_OS2 JA 82KRC OASiS Control panel installation manual This manual is valid for control panel JA 82KRC The control panel can be configured by a PC running OLink software ...

Страница 2: ...dible alarms 13 12 21 Wireless siren alarm enabled IW and EW 13 12 22 Auto bypass user approval via the key 13 12 23 Final door detectors 13 12 24 Partial setting arming or system splitting 14 12 25 Automatic summer time daylight saving time 14 12 26 Tamper alarm in response to an increase in the number of triggered tamper sensors 14 12 27 Operating the PG outputs using 8 and 9 14 12 28 Permanent ...

Страница 3: ...e control panel does not allow for the simultaneous connection of both a wired and a wireless input to the same address Connecting to a wired input automatically disables the wireless input of the same address o Other hard wired inputs are provided by some wireless devices such as keypads door detectors and PIR movement detectors 1 1 Main features When triggered a detector or any other device conn...

Страница 4: ...or Maintenance modes 1 2 Optional system configurations In the European Union region follow the valid standards and rules especially series EN 501 xx The Oasis control panel complies with grade 2 The control panel must have one of the following configurations as a minimum At least two non backup battery sirens JA 80L or SA 105 communicator class ATS2 JA 80Y JA 80V or JA 80X At least one backup bat...

Страница 5: ... parallel resistors see the diagram below o For wiring examples see the below diagram TAMPER SIREN ACTIVATION TAMPER ACTIVATION TAMPER ACTIVATION TAMPER ACTIVATION ACTIVATION DOOR 1 DOOR 2 DETECTOR 1 DETECTOR 2 DETECTOR 3 Maximum of 5 detectors in one loop If you enroll a wireless device to address 01 to 04 the corresponding input terminal will be disabled o The same applies to input terminals 05 ...

Страница 6: ...e control panel for 1 second e g using a screwdriver This will enter enrollment mode on the control panel 4 Install batteries into the keypad not far from the control panel 5 The keypad generates a beep sound and enrolls to address 05 or 15 After that it indicates Enrollment 06 Device or Enrollment 16 Device 6 Press the key to exit enrollment mode and Service will be indicated on the keypad Warnin...

Страница 7: ...onnection to the control panel possibly due to excessive distance or it could be too close to the control panel closer than 2 meters is not permitted To re enroll a device first disconnect its battery Then wait about 10 seconds or to save time press and release its tamper switch to quickly discharge any remaining energy A sub control panel can be enrolled to a master control panel by keying in the...

Страница 8: ...ne multiple control panels in one UC or AC receiver 12 Control panel programming The most convenient way to program the system is to use a PC running OLink software The system can however also be programmed by keying in the sequences in section 12 1 The system should be in Service mode if not enter the following with the system unset 0 Service code the factory default is 8080 Enter the appropriate...

Страница 9: ...ng Entrance delay beeps 35x 351 YES 350 NO YES Setting arming confirmation by wired siren chirp 36x 361 YES 360 NO NO IW terminal only Siren always sounds during audible alarms 37x 371 YES 370 NO YES NO siren only sounds if the system is completely set armed Wireless siren alarms enabled IW EW 38x 381 YES 380 NO YES Auto bypass user approval via the key If a detector is active during setting armin...

Страница 10: ...as the effect or SET A or SET AB C has the effect or SET ABC or UNSET ABC In a split system a keyfob button pair assigned to section A SET UNSET A B SET UNSET B C SET UNSET ABC 61 nn r s Code card reactions and section assignment A code card may have the same kind of reaction as devices 62 nn r s nn address 01 to 50 r reaction 0 disabled incl tamper sensor 1 Natural this means for detectors select...

Страница 11: ...y alarm PG on excluding Panic Panic A PGX on Panic B PGY on 6 AC dropout PG on Fire PGX on dropout PGY on 7 ON OFF 8 2 seconds pulse The ON OFF and 2 second pulse functions can be controlled from the keypad by keying in 8 9 or using the arrow keys see 12 27 or they can be operated by a code or card These PG output functions can also controlled by signals from keyfobs or detectors see 12 41 Notes T...

Страница 12: ...aster code has no effect on other codes and cards Resets are recorded in the control panel memory and sent to the ARC if used Alarm Receiving Centre previously called a central monitoring station 12 12 Control panel enrollment to UC or AC modules or to a sub control panel Keying in 299 sends an enrollment signal to enroll the control panel to UC 82 or AC 82 receiving modules see 11 6 This sequence...

Страница 13: ...21 Wireless siren alarm enabled IW and EW This setting is for enabling and disabling wireless sirens in the system 3 8 1 wireless sirens enabled 3 8 0 wireless sirens disabled Note This setting has no effect on wired output terminals Factory default setting wireless sirens enabled 12 22 Auto bypass user approval via the key The system has a built in auto bypass function so that if any number of de...

Страница 14: ...unset immediately after the user sets unsets the system Assigning wireless devices access codes and keyfobs to various sections of the system has no effect in this mode Partial setting is especially suitable for homes and apartments where the user wishes to protect different parts of the premises during the day Detectors can be assigned to three sections A B and C Using setting arming key A on the...

Страница 15: ...her or a JA 80V version XA64005 or higher is installed 12 32 Annual check notification This sequence enables the user and installer to be notified of the necessary time for an annual technical check 6900 notification disabled 6901 notification enabled Notes An annual technical inspection notification is displayed as text on the keypad display and can also be sent as an SMS to the end user and or i...

Страница 16: ...e hard wired input terminals in the control panel or enrolled wireless devices r is the reaction index from 0 to 9 see Table 2 s is the section 1 A 2 B 3 C only has an effect if partial setting or system splitting is used except for PG output control Guidance on assignment to sections Assigning keyfobs with natural reactions to sections s button Unsplit system Partial setting Split system or set s...

Страница 17: ...rd has a natural reaction i e r 1 then its reaction is set unset set etc the same as reaction r 9 in table 2 A code card can also have an alarm reaction designated to it similar to detectors Factory default setting all codes cards from 01 to 50 have a natural reaction set unset and are assigned to section C 12 42 Enrollment by keying in production codes This sequence allow the enrollment of device...

Страница 18: ...ext is stored in the non volatile memory of keypads so power disconnection will not erase any stored text Convenient text editing is possible using a PC running OLink software Besides device names keypads also use so called internal text such as service maintenance mode etc and this text can also be edited via OLink software by selecting Settings on the menu and then keypad text After editing keyp...

Страница 19: ... codes and cards from 01 to 50 are erased If a user has both a code and a card then it is possible to program whether both a code and card must be presented to the system for system access or whether only one of them is required see 12 37 The system does not allow the same code or card to be programmed to multiple users if it is desired to move a code card to another user the card code has to be e...

Страница 20: ...0 can be scrolled through with the A indicator showing whether a code is programmed or not and the B indicator showing whether a card is programmed or not 4 To exit this code card display mode press the key 5 To exit maintenance mode press the key To change access codes and cards use sequence 6 MC nn NC see 13 2 The most convenient way to administer codes is by using a PC running OLink software 13...

Страница 21: ...control panel The wireless keypad does not indicate entrance delays by beeping If the keypad is only battery powered then it turns off 20 seconds after the last time a key was pressed To indicate entrance delays first wake it up Install an ordinary magnetic sensor to the entrance door wiring it to the keypad input so that opening the door wakes up the keypad and reports to the control panel Altern...

Отзывы: