background image

 

Actions' table 

no splitting 

split  

no action 

no action 

arm all 

arm all 

2 disarm disarm 

all 

3  partial arming

arm A 

4  partial arming

arm B 

5 disarm  disarm 

6 disarm  disarm 

3.4  Automatic arming / disarming 

 

The system can automatically arm and disarm for a requested period of a day. 

While in the user more, up to ten instructions (time & action) can be programmed 
in the period of one day. 

To switch the control panel to the user mode enter 

F 0 master code

. User 

mode will be indicated by a  

U

 on the keypad. To program automatic arming enter: 

 
 

64 n a hh mm 

where: 

n

 = instruction number from 0 to 9  

a

 = action (see the actions' table) 

hh

 = hours (from 00 to 23) 

mm

 = minutes (from 00 to 59) 

 

Example: to program an automatic complete 
arming of the system at 21:15 everyday 
enter: 64 0 1 21 15 

 

 

Notes: 

• 

If any automatic action is selected, it will be preformed everyday at the 
programmed time, following the internal control panel clock. 

• 

The automatic arming and disarming can be overridden manually anytime 
(by a user code or a remote control) 

• 

If the control panel is in the requested arming mode before the action 
time, the programmed action will not change the arming 

• 

Factory default setting - all instructions are set for no action 

 

To 

exit user mode,

 press the 

N key

 

3.5 Bypass  

 

The supervisor can bypass (switch off) particular zones (potential sources of 

alarms) while in the user mode. If a zone is bypassed, it can’t trigger an alarm.  

 

To switch the control panel to the user mode enter 

F 0 master code

. User 

mode will be indicated by a 

U

 on the keypad.  

 

 

To set up bypass: 

 

1. Press 

key 

 1  

to open the bypass menu. 

2. With key 

and 

7

 you can scroll all potential alarm sources (wireless 

detectors are distinguished with the symbol 

). 

3.  Select the source (detector, wired input…) which you want to bypass and: 

a.  either press key 

2

 for 2 seconds to bypass the source for the next 

arming period (confirmed by flashing Battery LED); 

b.  or press key 

3

 for 2 seconds to bypass the source permanently 

(confirmed by the Battery LED being permanently lit); 

Alarm system JA-63 „PROFI“ 

- 10 - 

MGK51501 

Содержание JA-63 PROFI"

Страница 1: ...JA 63 Profi User manual Pod Skalkou 33...

Страница 2: ...2 11 Appliance control 8 3 User s settings 8 3 1 New master code 8 3 2 User codes setting 9 3 3 Internal clock setting 9 3 4 Automatic arming disarming 10 3 5 Bypass 10 4 Telephone communicator progra...

Страница 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Страница 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Страница 5: ...11 press the A button system will beep once and the exit delay countdown will start B A ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exi...

Страница 6: ...depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the JA 60D keypad enter F7 On the remote control RC 11 press the A an...

Страница 7: ...stem history can be viewed using a PC with Comlink software Alarms and failures can also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times...

Страница 8: ...ntrol an electrical appliance light heating ventilation etc In such a case users can operate the device Locally with keypad entering F81 ON or F80 OFF The JA 60D keypad does not support this feature R...

Страница 9: ...the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in a safe place The JA 60D keypad has its own access codes which can be...

Страница 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Страница 11: ...mmunicator and if the installer enabled the supervisor to modify the communications settings only then will the following programming be possible 4 1 Telephone communicator testing Testing is possible...

Страница 12: ...user mode To switch the control panel to the user mode enter F 0 master code User mode will be indicated by a U on the keypad If Jablotron s SMS server service is provided in your country check with...

Страница 13: ...8 Pager dialing can be deleted with 7 F0 F5 To exit user mode press N 5 System testing The supervisor should test the system monthly For testing the control panel should be in the user mode Enter F0 m...

Страница 14: ...l battery capacity can shorten the battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be...

Страница 15: ...Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 SMS message o Pager Timers exit entrance del...

Страница 16: ...location in the house detectors type reaction A B S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 WIRELESS DETECTORS 16 1 2 3 WIRED INPUTS 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Отзывы: