Telephone line 

indicated event (Tamper or Failure) was caused 

by the telephone line 

 

digital bus 

indicated event (Tamper or Failure) was caused 

by a device (keypad or PC) connected to the 

digital bus 

 

communication 

failure 

wireless keypad lost connection with the control 

panel 

 

error 

self testing error – call installer 

tab. 1 

 

88

 display specifies mode of the control panel: 

 

user mode 

authorized supervisor can test, bypass zones, change 

batteries, record voice messages, program tel. 
numbers and adjust internal clock in this mode

 

 

home arming 

system is partially armed – particular detectors are 

bypassed  (someone remains in the house) 

 

A section armed

A section is armed (split system) 

 

B section armed

B section is armed (split system) 

 

complete 

arming 

system is completely armed  

 

bypass 

warning that some detectors are bypassed – 

indicated while arming 

 

key pressed 

waiting for more data to complete the entry 

 

programming 

mode 

for installer programming and testing 

tab. 2

 

2  Controlling the system 

 

The system can by controlled by keypads, remote controls or by a PC with the 

Comlink Software. 

   

User codes   

 

Can be used to arm and disarm the system or to reset an alarm. There can be up to 

14 different user codes for individual  users. The system stores to its memory which 
code was used for which operation as well as the  time &date of usage. This data can 
go to a  Central monitoring station and can also be viewed using a  PC with Comlink 
software.  

All user codes are empty as a factory default and should be programmed by the 

supervisor (see section 3.2).  

Alarm system JA-63 „PROFI“ 

- 4 - 

MGK51501 

Содержание JA-63 PROFI"

Страница 1: ...JA 63 Profi User manual Pod Skalkou 33...

Страница 2: ...2 11 Appliance control 8 3 User s settings 8 3 1 New master code 8 3 2 User codes setting 9 3 3 Internal clock setting 9 3 4 Automatic arming disarming 10 3 5 Bypass 10 4 Telephone communicator progra...

Страница 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Страница 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Страница 5: ...11 press the A button system will beep once and the exit delay countdown will start B A ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exi...

Страница 6: ...depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the JA 60D keypad enter F7 On the remote control RC 11 press the A an...

Страница 7: ...stem history can be viewed using a PC with Comlink software Alarms and failures can also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times...

Страница 8: ...ntrol an electrical appliance light heating ventilation etc In such a case users can operate the device Locally with keypad entering F81 ON or F80 OFF The JA 60D keypad does not support this feature R...

Страница 9: ...the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in a safe place The JA 60D keypad has its own access codes which can be...

Страница 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Страница 11: ...mmunicator and if the installer enabled the supervisor to modify the communications settings only then will the following programming be possible 4 1 Telephone communicator testing Testing is possible...

Страница 12: ...user mode To switch the control panel to the user mode enter F 0 master code User mode will be indicated by a U on the keypad If Jablotron s SMS server service is provided in your country check with...

Страница 13: ...8 Pager dialing can be deleted with 7 F0 F5 To exit user mode press N 5 System testing The supervisor should test the system monthly For testing the control panel should be in the user mode Enter F0 m...

Страница 14: ...l battery capacity can shorten the battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be...

Страница 15: ...Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 SMS message o Pager Timers exit entrance del...

Страница 16: ...location in the house detectors type reaction A B S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 WIRELESS DETECTORS 16 1 2 3 WIRED INPUTS 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Отзывы: