1. INTRODUCTION

Thank you for choosing the JA-10 security system. This manual is 

intended for the set of the JA-14K control panel and JA-10E or JA-15E 
keypads. This system is a unique indoor solution for commercial, home and 
personnel security which offers the use of wireless and wired devices. 
The JA-10 is very easy to control. Simplicity of control consists of two steps, 
authorization with a code or an RFID tag followed by pressing an individual 
function button on a keypad. The alarm system can be also controlled just 
by authorization. The JA-10 offers a wide range of detectors with timeless 
design and can be operated from anywhere owing to complete remote 
control access via our application for smart phones.

The JA-10 system is designed for up to 16 users and it can be divided into 

4 separate sections. Up to 32 devices can be connected and the system 
offers 4 multi-purpose programmable outputs (e.g. home automation).

WARNING:

The JA-10 alarm system is intended to be installed and programmed by 

professionals. A user can only administrate user functions and access rights 
to the alarm system.

The alarm system can be programmed to utilize various ways of control which are selectable during 

installation as system profi les such as:

 o 

Default Jablotron

 o 

EN 50131, gr.2

Some of the user functions will be limited depending on the selected profi le. Request a detailed function 

list from your service technician.

The alarm system can be controlled by a system keypad and a few other ways. To unset the alarm, 

authorization in the form of user identifi cation is always required. The system detects the identity of the 
users and allows them to operate those parts of the system which they have been assigned to control. 
You can choose from different ways of setting with or without authorization. When setting without 
authorization is used, you don’t have to authorize yourself because it is possible to set the system just by 
pressing a function button on a keypad. The control panel may be confi gured to be controlled simply by 
authorization. The user name, date, and time are recorded and stored in the system‘s memory every time 
the system is accessed. This information is available indefi nitely. Any user can also cancel a triggered alarm 
(stop sounding sirens) just by authorization in any part of the system (depending on their access rights). 
However, that does not automatically unset the system (unless the system’s default setting is changed).

Note: Depending on the confi guration of the installation and system settings, some of the options described 
below may not be available. Consult the confi guration of the installation with your service technician.

WARNING:

 The alarm system monitors the number of incorrectly typed user codes and use of 

incorrect access cards. A tamper alarm will be triggered after 10 incorrect attempts at authorization 
and the control panel will be temporarily blocked depending on the alarm system confi guration 
(a selected system profi le).

2. OPERATING THE JA-10 SYSTEM

Содержание JA-10 Series

Страница 1: ...JABLOTRON 10 USER MANUAL EN Grade 2 certified...

Страница 2: ...MNX501001 Manufacturer JABLOTRON ALARMS Pod Skalkou 33 466 01 Jablonec nad Nisou Czech Republic www jablotron com For questions and further information contact your installer Installed by...

Страница 3: ...PHONE APP 13 2 5 OPERATING THE CONTROL PANEL BY SMS 13 2 6 OPERATING THE CONTROL PANEL USING THE VOICE MENU 13 2 7 PG OUTPUTS CONTROL 14 2 7 1 KEYPAD FUNCTION BUTTONS 14 2 7 2 USER KEYPAD AUTHORIZATIO...

Страница 4: ...2 6 WHAT IS MYJABLOTRON 17 7 PERIODICAL MAINTENANCE 17 8 TECHNICAL SPECIFICATIONS 18 9 GLOSSARY OF TERMS 19 TABLE OF CONTENTS...

Страница 5: ...our service technician The alarm system can be controlled by a system keypad and a few other ways To unset the alarm authorization in the form of user identi cation is always required The system detec...

Страница 6: ...on in order to control sections and PG outputs assign them with access codes or RFID tags It has permission to erase the alarm and tamper memory in assigned sections When Administrator restricted Serv...

Страница 7: ...ty The number of code combinations depends on the con guration WAYS TO IMPROVE PROTECTION AGAINST GUESSING THE VALID CODE o Using a code with more digits 6 digit codes o More advanced types of authori...

Страница 8: ...o Mobile phone via SMS o Mobile phone using the voice menu WARNING Remote control may be limited depending on the range of security and the selected System pro le 2 2 USING THE SYSTEM KEYPAD STATUS I...

Страница 9: ...horization Authorization can be done by entering an access code on the keypad or using an RFID tag assigned to a particular user Each user can have one code and one RFID tag The control panel supports...

Страница 10: ...ing setting the system provided this option is activated in the control panel con guration Displays a list of all blocked detectors in sections to which a user has access rights Displays a list of all...

Страница 11: ...has expired then the control panel will unset again Unsuccessful setting is indicated by a system indicator ashing yellow reported to the ARC and indicated by an external siren applies to the securit...

Страница 12: ...r the alarm when somebody moves inside the section 1 When you enter the building triggering a detector with a Delay reaction the system starts indicating an entrance delay with a continuous tone the s...

Страница 13: ...to use this feature Example Valid code 9999 Code for unsetting under duress 9990 2 2 5 TERMINATING A TRIGGERED ALARM A triggered alarm in progress is indicated by the status indicator and the function...

Страница 14: ...linked to speci c users which will ensure their identi cation and prevent sending SMS no ti cations to the user who is interacting with the control panel at the moment if noti cation parameters are se...

Страница 15: ...ds CODE_SET_2_4 The commands to control the programmable outputs can be progra mmed by a service technician For example you may choose GARAGE DOOR as your command to open garage door It is also possib...

Страница 16: ...g an RIFD tag The PG output must be con gured to activate from a designated keypad 2 7 3 REMOTE CONTROL By pressing an assigned remote control button 2 7 4 DIALLING IN Each telephone number stored in...

Страница 17: ...s with your service technician If the premises are guarded by a security agency consult them as well 4 1 CHANGING USER ACCESS CODE Only the system administrator and the service technician can change t...

Страница 18: ...When creating new users it is necessary to assign them with access permissions rights to individual sections and programmable outputs control with required authorization The security system stores al...

Страница 19: ...User maintenance consists of keeping the individual devices clean Some devices may require regular testing which is always described in the individual manual of such device e g re detectors 6 WHAT IS...

Страница 20: ...A primary supply with a charged backup battery event history approx 7 million latest events incl date and time system reaction to communication loss Fault or tamper according to the pre set pro le BUS...

Страница 21: ...tioning parts called sections Each section can have its assigned detectors keypads as well as sirens users and their telephone num bers There can be up to 4 sections per system Programmable Outputs PG...

Страница 22: ...20 NOTES...

Страница 23: ......

Страница 24: ...M ENJA10 USER...

Отзывы: