Страница 1: ...JABLOTRON 10 USER MANUAL EN Grade 2 certified...

Страница 2: ...MNX501001 Manufacturer JABLOTRON ALARMS Pod Skalkou 33 466 01 Jablonec nad Nisou Czech Republic www jablotron com For questions and further information contact your installer Installed by...

Страница 3: ...PHONE APP 13 2 5 OPERATING THE CONTROL PANEL BY SMS 13 2 6 OPERATING THE CONTROL PANEL USING THE VOICE MENU 13 2 7 PG OUTPUTS CONTROL 14 2 7 1 KEYPAD FUNCTION BUTTONS 14 2 7 2 USER KEYPAD AUTHORIZATIO...

Страница 4: ...2 6 WHAT IS MYJABLOTRON 17 7 PERIODICAL MAINTENANCE 17 8 TECHNICAL SPECIFICATIONS 18 9 GLOSSARY OF TERMS 19 TABLE OF CONTENTS...

Страница 5: ...our service technician The alarm system can be controlled by a system keypad and a few other ways To unset the alarm authorization in the form of user identi cation is always required The system detec...

Страница 6: ...on in order to control sections and PG outputs assign them with access codes or RFID tags It has permission to erase the alarm and tamper memory in assigned sections When Administrator restricted Serv...

Страница 7: ...ty The number of code combinations depends on the con guration WAYS TO IMPROVE PROTECTION AGAINST GUESSING THE VALID CODE o Using a code with more digits 6 digit codes o More advanced types of authori...

Страница 8: ...o Mobile phone via SMS o Mobile phone using the voice menu WARNING Remote control may be limited depending on the range of security and the selected System pro le 2 2 USING THE SYSTEM KEYPAD STATUS I...

Страница 9: ...horization Authorization can be done by entering an access code on the keypad or using an RFID tag assigned to a particular user Each user can have one code and one RFID tag The control panel supports...

Страница 10: ...ing setting the system provided this option is activated in the control panel con guration Displays a list of all blocked detectors in sections to which a user has access rights Displays a list of all...

Страница 11: ...has expired then the control panel will unset again Unsuccessful setting is indicated by a system indicator ashing yellow reported to the ARC and indicated by an external siren applies to the securit...

Страница 12: ...r the alarm when somebody moves inside the section 1 When you enter the building triggering a detector with a Delay reaction the system starts indicating an entrance delay with a continuous tone the s...

Страница 13: ...to use this feature Example Valid code 9999 Code for unsetting under duress 9990 2 2 5 TERMINATING A TRIGGERED ALARM A triggered alarm in progress is indicated by the status indicator and the function...

Страница 14: ...linked to speci c users which will ensure their identi cation and prevent sending SMS no ti cations to the user who is interacting with the control panel at the moment if noti cation parameters are se...

Страница 15: ...ds CODE_SET_2_4 The commands to control the programmable outputs can be progra mmed by a service technician For example you may choose GARAGE DOOR as your command to open garage door It is also possib...

Страница 16: ...g an RIFD tag The PG output must be con gured to activate from a designated keypad 2 7 3 REMOTE CONTROL By pressing an assigned remote control button 2 7 4 DIALLING IN Each telephone number stored in...

Страница 17: ...s with your service technician If the premises are guarded by a security agency consult them as well 4 1 CHANGING USER ACCESS CODE Only the system administrator and the service technician can change t...

Страница 18: ...When creating new users it is necessary to assign them with access permissions rights to individual sections and programmable outputs control with required authorization The security system stores al...

Страница 19: ...User maintenance consists of keeping the individual devices clean Some devices may require regular testing which is always described in the individual manual of such device e g re detectors 6 WHAT IS...

Страница 20: ...A primary supply with a charged backup battery event history approx 7 million latest events incl date and time system reaction to communication loss Fault or tamper according to the pre set pro le BUS...

Страница 21: ...tioning parts called sections Each section can have its assigned detectors keypads as well as sirens users and their telephone num bers There can be up to 4 sections per system Programmable Outputs PG...

Страница 22: ...20 NOTES...