18
8. TECHNICAL SPECIFICATIONS
PARAMETER
JA-100K
Type of installation
Fixed installation
Nominal control panel voltage / frequency / fuse
~ 230 V / 50 Hz, T200 mA fuse 250 V 5 x 20 mm
~ 115 V / 60 Hz, T400 mA fuse 250 V 5 x 20 mm
Operation voltage range
~ 195 V ÷ 250 V
~ 110 V ÷ 120 V
Electric power / current
Max 23 VA / 0.1 A
Protection class
II.
Back-up battery
12 V; 2.6 Ah max. (lead-acid)
Low battery voltage (fault indication)
≤ 11 V
Maximum battery charging time
48 ÷ 72 h
BUS voltage / max. voltage ripple (red-black)
12,0 ÷ 13,8 V DC / ± 100 mV
Max. continuous consumption from the control panel BUS +RJ
400 mA permanently (1000 mA for 5 minutes)
@ 12 hours backup (2.6 Ah)
LAN OFF: 125 mA – consumption of external modules
LAN ON: 85 mA – consumption of modules
Max. number of devices
32
Alarm connection
JABLOTRON BUS – dedicated wired connection
Wireless connection (with JA-111R) – unspecifi ed wireless co-
nnection, JABLOTRON wireless protocol
Alarm system classifi cation
Security grade 2 / environmental class II
@ according to standards
EN50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3,
EN 50131-10, EN 50136-1, EN 50136-2
@ environment
Indoor general
@ operational temperature / humidity
-10 °C to +40 °C, relative humidity 75%, no condensation
@ power
Type A – primary supply with a charged backup battery
@ event history
approx. 7 million latest events, incl. date and time
@ system reaction to communication loss
Fault or tamper – according to the pre-set profi le
@ BUS - up to 10 s
@ wireless communication - in 2 hrs (report)
@ wireless communication - in 20 min block system to be set
@ reaction to invalid code entry
After 10 wrong code entries a tamper alarm is triggered and
according to the selected profi le it blocks all control devices for
10 min
@ ATS classifi cation
Supported ATS classes : SP2 – SP 5, DP2 – DP3
SPT:
type
Z
Operation type:
Pass-Through
Built-in LAN:
SP2 – SP5 (with IP protocol)
JA-190Y
SP2 – SP5 (with IP protocol)
JA-190X
SP2 (with Contact ID protocol)
LAN + JA-190Y
DP2 – DP3 (with IP protocol)
LAN + JA-190X
DP2 (with IP / CID protocol)
@ ATS transferring protocols
JABLO IP, SIA IP, Contact ID, JABLO SMS
@ ATC protection against substitution and data protection
JABLOTRON protocol: Proprietary AES encryption
with minimum 128 bit key
ANSI SIA DC-09.2012 protocol with 128 bit AES encryption
LAN communicator
Ethernet interface CAT 5 (RJ-45)
Dimensions
268 x 225 x 83 (mm)
Weight
1450 g
Basic parameters of the JA-111R module
868.1 MHz, < 25 mW, GFSK < 80 kHz
Radio emissions
ETSI EN 300 220-2 (the JA-111R module)
EMC
EN 50130-4, EN 55032, ETSI EN 301 489-1, ETSI EN 301 489-3
Electric safety
EN 60950-1
Operational conditions
ERC REC 70-03, ERC DEC (98) 20
Certifi cation body
TREZOR TEST
Содержание JA-10 Series
Страница 1: ...JABLOTRON 10 USER MANUAL EN Grade 2 certified...
Страница 22: ...20 NOTES...