9
5 - Release the "OFF" button and close the remote control handset.
6 - To change the function state repeat the procedure from the point 1 (at each repetition of the
procedure the function changes state).
- PROTECTIONS.
When the system is armed the status check LED switches constant on, after 30 seconds the LED
flashes. The i
gnition key, seat/bonnet/sidestand and wires cut
protections are active
5 seconds
after the arming,
while the
shocks/movement sensor
is active when the
status check LED
flashes.
- SLEEP MODE (POWER SAVE).
To protect the motor vehicle battery the system operates a constant monitoring of the power supply
voltage and/or reduction of the available functions in the time.
MOTOR VEHICLE BATTERY MONITORING: when the system is disarmed, if the battery reaches the
threshold of 8V the alarm places in “SLEEP MODE” .
SLEEP MODE WHEN THE ALARM IS DISARMED: when the alarm is disarmed, after 10 days the system
places automatically in “SLEEP MODE”. To reactivate the alarm switch the ignition key on.
SLEEP MODE WHEN THE ALARM IS ARMED: after 5 days the system doesn’t accept the handset
command anymore, but all the protections remain active. The normal operation is restored in case of
alarm. In this condition the first cycle is preceeded by a pre-alarm signal (beeps) of 10 seconds.
During the pre-alarm it is possible to disarm the system.
- INDICATORS EMERGENCY FLASH (only with GT889).
- To activate the indicators flash turn the motor vehicle ignition key on and press the “OFF” handset
button.
Note 1:
the flash continues even removing the key.
Note 2:
during the indicators flash is
however possible to arm/disarm the system.
- To stop the indicators flash turn the motor vehicle ignition key on and press the “OFF” handset button.
- SERVICE MODE.
For the motor vehicle servicing, i.e. in winter, it is possible to place the alarm in SERVICE MODE.
1 - Turn the ignition key on and press the “ON” handset button. The system confirms the operation with
3 flashes of the RED LED.
2 - Turn the ignition key off and after 120 seconds the system places in POWER SAVE with a current
consumption of very few microampere.
3 - To come out from the SERVICE MODE switch the ignition key on and arm the alarm with the handset
during the 120 seconds.
- BACKUP BATTERY RECHARGE.
The device is equipped with internal battery to manage possible alarms due to tamperings on the
electrical system when the thesystem is armed. The battery recharge occurs only with the motor
vehicle ignition switched on. To recharge completely the battery 24 hours are needed.
-
ALARMS CHECK CONTROL AND ANOMALIES.
If during the surveillance state an alarm has been detected (4 indicators flashes and 4 beeps to the
disarming) or there is anomaly it is possible to check the cause.
When the alarm is disarmed switch the ignition key on and check the LED flash as indicated in the
ALA RMS SIGNAL TABLE and ANOMALIES SIGNALS TABLE.
- Motor vehicle low battery indication:
when disarming with the handset if the motor vehicle
battery is at 11,6V the system doesn’t activate the indicators and after the normal acoustic signalling
emits 5 anomaly beeps and when it is triggering it doesn’t activate the indicators.