background image

JABLOTRON

ALARMS

a.s.

Pod

Skalkou

4567/33

46601

Jablonec

n.

Nisou

Czech

Republic

www

.jablotron.com

||

|

The JA-150TP Wireless indoor thermostat

The JA-150TP Wireless indoor thermostat

1 / 3

MMX53105

The JA-150TP is a component of the 

JABLOTRON 100

system.

It serves for the measuring and regulation of temperature by controlling 
an assigned PG output of the control panel. The thermostat is fully 
supported by MyJABLOTRON, which allows to control the temperature 
and change its settings remotely. There is a graph of the currently 
measured temperature and its history in MyJABLOTRON. Pre-set limits 
can be set for every thermostat notification about overshooting
or undershooting a temperature. It also has a weekly program where 
it can switch between comfort and economical temperatures, manual 
mode and Standby mode. In total (including wireless and BUS versions) 
up to 4 thermostats can be used in the system. Thermostat can control 
only one PG output. The product should be installed by a trained 
technician with a valid certificate issued by an authorized distributor.

Figure 1: 1 – Knob combined with a button; 2 – Cover tab

Description

The thermostat measures temperature based on which it switches

a selected PG output on / off in the control panel. The currently 
measured temperature is displayed on the LCD display where the user 
can find additional information, see Figure 3. When the currently 
measured temperature is out of the pre-set 

temperature range (-10 °C 

to +70 °C)

then it displays 

Hi °C

or 

Lo °C

.

The individual temperature levels of the thermostat are shown

on Figure 2. All temperature levels can be set in MyCOMPANY. Values 
(levels) from 

(D) to

(E), are editable also directly 

on the thermostat, see 

Control / operation

.

Figure 2: A – Low temperature, B – Temperature in Standby mode,

C – Lower temperature limit pre-settable by user, D – Economical 

temperature, E – Comfort temperature, F – Upper temperature limit

pre-settable by user, G – High temperature

Control / operation:

Operation is very simple. Setting (changing) the temperature 

is performed by turning the knob (1) and performing confirmation 
by pressing it (or automatically after 5 sec). 

To see the

current time and day of the week

on the LCD display 

perform a double press (2x /1 sec) of the knob (1).

In the 

Program

and 

Manual mode

it is possible to 

show the required 

temperature

by pressing the knob (1).

The

Economical 

and 

Comfort 

temperature can be done 

in the thermostat internal menu. Enter the internal menu by pressing 
the knob (1) longer – approx. 6 sec. The first option to be set 
is the

Comfort temperature

(

symbol is ON and °C flashes). 

Turning the knob (1) performs selection of the required temperature. 
By pressing the knob (1) confirm the pre-set value and continue with 
settings of the

Economical temperature 

(symbol 

is ON and °C 

flashes). By pressing the knob (1), store all the pre-set values and 
return to the main screen. If the thermostat internal menu is open for 
10 sec with no activity (pressing or turning the knob), it will automatically 
quit the internal settings without saving the pre-set values.

Figure 3: 3 – Internal settings entry from F-Link SW/ communication 

fault; 4 – Symbols of comfort

and economical  temperature;

5 – Days of week; 6 – heating activated when thermostat is blocked;

7 – Standby mode activated; 8 – Heating, flashing

Ÿ

– thermostat 

blocked by open window for example; 9 – Axis of heating periods;

10 – Symbols for showing the temperature, time and text; 11 – Low 

battery indicator; 12 – Showing of pre-set / required temperature

Thermostat operation modes:

The thermostat suits various premises types, therefore it offers 

a few operating modes. By pressing the knob (1) for approx. 3 sec 
it can switch between its individual modes. The thermostat can 
be pre-set via the MyJABLOTRON application very comfortably,
see the MyJABLOTRON chapter.

Program: 

The thermostat has a weekly program.

It switches between the Economical 
and Comfort (4) temperature in pre-set 
intervals. This temperature is compared 
with the currently measured temperature

and based on the difference between the temperatures it switches
the heating via a PG output (the heating symbol 

Ÿ

is ON when the 

PG output is switched on). The user can simply change the heating 
temperature, see 

Temporary manual temperature

.

The heating plan can be set individually for every day. Each day can 

have up to 4 heating intervals for the Comfort temperature. 
The minimum heating period is 15 minutes. Setting of the Program 
mode is possible only using the MyJABLOTRON or MyCOMPANY.

Temporary manual temperature (TMT):

It serves for a fast temperature change 

when the 

Program

mode is activated. 

To trigger TMT mode turn the knob (1). 
All elements indicating 

Program

mode 

remain the same, only the  /

(4) symbol

disappears. The thermostat remains in this mode until the next manual 
temperature correction or until the moment when the pre-set program 
initiates next change between Comfort and Economical temperature.

Manual: 

In 

Manual mode

set required temperature

by turning the knob (1) which is then
constantly maintained.

The measured 

temperature is only visible on the LCD. 
When the PG output is switched on then 

the 

Ÿ

symbol appears.

Standby

:

This mode can only be activated and 

deactivated from MyJABLOTRON. 
The thermostat maintains the temperature 
that was pre-set for the Standby mode. 
The currently measured temperature 

is displayed on the LCD and the „Stby“ symbol appears in the upper 
right corner. The 

Standby

mode temperature can be set 

in MyJABLOTRON or MyCOMPANY. This mode is meant to keep 
the temperature level to protect the premises against freezing when 
there is nobody inside for longer time.

Other functions:

Blocking: 

The PG output switching can be blocked by a status mode 

detector such as a magnetic detector, by another PG output 
or by the status of a section. It ensures that the thermostat won´t heat 
when a window or a door is open or any other blocking condition 
is fulfilled. Blocking of the PG output is indicated by Heating (8) symbol
flashing. When blocking is activated and the currently measured 
temperature drops below the Standby mode pre-set temperature, then 
blocking is overcome and the PG output is switched on – anti-freeze 
protection (signalled by the   symbol (6)). For situations when
the temperate would tend to still drop, the thermostat reaction 
to a low temperature can be set, see chapter 

Setting the thermostat

properties in the F-Link software

.

Отзывы: