background image

The JA-150TP Wireless indoor thermostat

The JA-150TP Wireless indoor thermostat

2 / 3

MMX53105

Switching to the economical temperature when the system 

is set:

The thermostat in the 

Program

mode can react 

to setting / unsetting the section, to which it is assigned. When 
the section is set, it switches at once to the

Economical temperature 

(if the thermostat has already heated to the 

Economical temperature,

nothing changes). The thermostat still follows a pre-set timed heating 
plan and the PG output switches on when it goes from the

Economical 

to 

Comfort temperature

even if the section is already set. 

So the heating can be activated earlier than when the users come back 
home and unset the system. It is valid for a fully and partially set 
sections. All settings can be performed in the MyCOMPANY.

Installation

The product can only be used in an indoor environment. Install the 

thermostat 1.5 m above the floor in a place where there is good natural 
air circulation. Don´t install the thermostat where the measuring 
can be influenced by drafts, sunlight, heaters or any other undesirable 
effects. 

Figure 4: 13 – Battery holders; 14 – production code;

Installation procedure:

1. Release the front thermostat housing by pressing the tab (2),

by screwdriver for instance.

2. Install the rear part of the thermostat at the chosen place (tab facing

down).

3. Follow the control panel installation manual. Basic procedure:

a.

There must be a JA-11xR radio module installed in the system.

b.

Go to the 

F-Link

software, select the required position 

in the 

Devices

tab window and launch enrollment mode 

by clicking on

Enroll

option.

c.

When you insert both batteries into the battery holder (13) 
it sends an enrollment signal and the thermostat is thus enrolled 
to the required position. When the enrollment procedure is done 
successfully (proper communication) the exclamation symbol (3) 
disappears from the thermostat’s LCD display.

4.

Put back the front thermostat part and close it.

5.

Using F-Link SW and the option Internal setting at the required 
thermostat select the PG output which will be controlled and other 
system settings. See more details in the chapter: Setting 
the thermostat properties.

6.

Other settings can be done in the MyCOMPANY. If the system has 
not been registered yet, it must be registered first (if needed ask 
your authorised distributor for help). When the system is registered 
already and only the thermostat has been added, then leave 
the service mode to upload new system configuration 
to MyJABLOTRON (ussually within 15 minutes).

7.

When registration is finished, pre-set the thermostat via 
the MyCOMPANY

application, see the chapter 

Setting 

the thermostat properties in MyCOMPANY.

Notes:

The thermostat can also be enrolled to the system by entering 
its production code (14) in the F-Link software. All digits 
of the production code are required. (Example: 1400-00-0000-
0001).

Setting the thermostat properties in the

F-Link software

Basic settings can be done in the F-Link SW in the internal settings 

of the specific thermostat. Where the following parameters can be set:

Controls PG:

(*No) Select which PG output will be controlled 

by the thermostat. The reaction of the PG has to be set to ON / OFF 
and must not be inverted. Thermostat can control only one PG output.

Reaction to high temperature:

(*None) The selection of the offered 

options determines the reaction when a

high temperature

is reached. 

Fire  alarm,  Fire  instant,  Report  A,  Report  B,  Report  C,  Report  D, 
Overheating or None.

Reaction to low temperature: 

(*None) The selection of the offered 

options determines the reaction when a

low temperature

is reached.

Report A, Report B, Report C, Report D, Freezing or None.

High temperature:

(*60 ºC) The temperature can be set in the range 

of -9.9 °C to +70 ºC. When a pre-set temperature is exceeded,
the selected reaction is triggered. The value of the high temperature 
always has to be higher than the low temperature.

Low temperature:

(*3 ºC) The temperature can be set in the range 

of -10 °C to +70 ºC. When the pre-set temperature is undershot,
the selected reaction is triggered. 

Setting the thermostat properties 

in MyCOMPANY

For the settings of all thermostat parameters it is necessary to have

the Jablotron 100 system registered – see the 

Installation

chapter to get 

the details. A service technician pre-sets the thermostat 
in the MyCOMPANY. (it is supported web and mobile applications). 

In the MyCOMPANY, open 

Installation management

. At the

selected system on the 

Devices

tab select the cogwheel symbol 

at the required thermostat position. The setting window with following 
parameters is open: 

Highest and lowest temperature configurable by the user 

(-10 ºC 

to +40 ºC).

Comfort and Economical temperatures:

are pre-settable by 

the user in the range of the 

lowest temperature limit

to the

highest 

temperature limit.

Heating plan:

can be the same for the whole week, different for week 

days and the weekend or individual for every day. Using the 

button 

add individual intervals when the thermostat should heat to the

Comfort 

temperature

. If an interval should be erased, click on it and when the 

symbol appears, by clicking on it the selected interval can be erased.

Activate economical temperature when: 

None / Partially set / fully 

set section to which the thermostat has been assigned. 

Temperature in Standby mode:

(from -10 ºC to +15 ºC) this 

determines the temperature which is going to be maintained in Standby
mode or when 

Blocking

is activated.

High temperature

(from -9.9 ºC to +70 ºC), see the chapter called

Setting the thermostat properties in the F-Link software.

Low temperature

(from -10 ºC to +70 ºC), see the chapter called 

Setting the thermostat properties in the F-Link software.

Hysteresis 

(from 0 °C to 5 ºC) For example, if the hysteresis is set 

to 1 °C and the required temperature is 30 °C, then, the PG output 
is switched on when the temperature drops below 29 °C and the PG
output is switched off when it exceeds 30 °C.

Temperature correction:

(from -12.8 ºC to +12.7 ºC) This option can 

fix any possible thermostat measurement deviation from the real 
temperature in the premises.

MyJABLOTRON

In the MyJABLOTRON thermostats are shown at 

Thermostats 

and thermometers

, where all the measured values of all thermostats 

and thermometers enrolled to the system are saved. This data is stored 
and available for future use. Reading the temperatures is done 
automatically at a 5 minute interval. 

For every thermostat:

The current status is displayed (Name, Heating / Temperature 
reached, Current temperature, Required temperature, Mode, Graph 
of measured temperature)

The temperature can be temporarily changed 

The operation mode can be changed (Program, Manual, Standby)

Temperatures are shown in a graph in the selected time period 

and can be exported in various formats for future processing.

The user has authorization to edit some settings directly

in the MyJABLOTRON application. Select 

Settings

Æ

Thermostats

to open 

settings window with following parameters:

Basic settings:

Comfort and Economical temperatures
Heating plan

Advanced settings:

Temperature in Standby mode
Hysteresis 

(0 - 5 ºC)

Temperature correction