Publicatin
JP OM15
Jabiru J400
Owners Manual
Section: 3
.
ENGINE FIRE IN FLIGHT
1
Throttle
CLOSED
2
Fuel Shutoff Valve OFF
3
Mag Switches
OFF
4
Master Switch
OFF
5
Fuel Pump Switch
OFF
6
Cabin Air
OFF
7
Airspeed
80 KIAS
(if fire is not extinguished,
increase glide speed to find an
airspeed which will provide an
incombustible mixture).
8
Forced Landing
Execute
(as described in Emergency
Landing Without Engine Power).
.
ELECTRICAL FIRE IN FLIGHT
1
Master Switch
OFF
2
All Other Switches OFF
3
Vents/cabin air
OPEN
If fire appears out and electrical power is necessary for
continuance of flight:
4
Master Switch
ON
5
Fuses
CHECK
for faulty circuit,
DO NOT
reset or
replace.
6
Radio/Electrical
Switches
ON
one at a time, with delay after
each until short circuit is localised.
7
Land as soon as possible to inspect for damage
REVISION
0
Date SEPT 00
Page 3-6 of 6