MOUNTING THE J3C ACTUATOR TO 1/4 TURN VALVES 

J3C Actuators have mounting facilities in accordance with ISO:5211 and DIN:3337 allowing them, in many cases, to mount directly onto similarly compliant 
valves without the need for a mounting kit (bracket and drive adaptor/ connector). The main advantages of direct mounting the actuators is to greatly assist in 
ensuring concentricity of the actuator output drive with the valve stem which eliminates side loadings (which result in increased wear on the valve stem and 
seals), reducing the effects of backlash in the drive train as there are fewer parts connected, and allowing valves to be part dismantled for installation into the 
pipe without disturbing the valve to actuator connection. 

The  drive  being  inserted into  the  actuator’s female  output  drive  must  NOT  be  longer  than the  maximum  depth of  the  female  drive  when the 
assembly is bolted together. 

Resulting damage to the actuator and assembled components due to this assembly error will not be covered by our 

warranty. 

J3C Model 

Maximum 

torque Nm 

ISO:5211 

Output star 

drive 

Optional star 

output 

Special execution 

on request 

140 

170 

F07 & F10 

22 

17 

F12 x 22 star 

300 

350 

F07 & F10 

22 

17 

F12 x 22 star 

WEATHERPROOF RATING 

The J3C electric actuators have an ingress protection rating of IP67, which gives them total protection against 
almost all kinds of weather and allows the actuator to be submerged under less than 1m of water for no more 
than 30 minutes. However, it cannot withstand being hosed down or pressure washed, or deluged in water.  

If the J3C is to be exposed to hosing down or pressure washing, a plastic bag must be first put over the J3C 
actuator  to  protect  it  from  the  direct  hosing  down. Even in these  circumstances,  do  not  pressure  wash  the 
plastic bag close up. 

Damage caused by water ingress is therefore not normally covered by the warranty. 

RECYCLE AT END OF LIFE 

J+J is committed to the protection of the environment.   

Please remember at end of life to dispose of responsibly and if the facilities are available recycle. 

 

TECHNICAL SUPPORT 

Live technical support  is available during the following hours, UK time -

 

Page 11 

Monday to Thursday: 

09:00 to 17:00 hrs 

Friday: 

09:00 to 16:00 hrs 

Tel: 

+44(0)1629 55577 

Out of office hours: 

 

Web: 

jjautomation.com 

MOUNTING ORIENTATION 

J3C actuators should never be installed with the actuator 
underneath the valve, or below the horizontal. 

 

OK 

 

OK 

 

PROHIBITED

 

Содержание H140

Страница 1: ...AFE and or MODULATING plug and play function conversion kits J3C140PPK A4 IOM MAIN Rev 1 Aug 17 Models 140 300 FAILSAFE AND OR MODULATING FUNCTION CONVERSION J3C FAILSAFE ACTUATOR WITH BSR PLUG PLAY K...

Страница 2: ...tion The user friendly BSR failsafe plug and play function conversion kit is quick and easy to install and can be configured on installation to send the J3C electric actuator to either the closed posi...

Страница 3: ...tment on site The J J electric actuator range is guaranteed for 12 months from date of despatch from the manufacturer against all types of manufacturing and material defects Actuators that have failed...

Страница 4: ...nto the base as described above with the battery wires at the top as shown in Photograph 2 Secure the first battery with the plastic plate and screw from the plastic bag as indicated There are 2 pegs...

Страница 5: ...Secure with screw from plastic bag as indicated in the yellow ring in Photograph 4 Photograph 4 Photograph 5 Step 5 Fit the black plastic jumper as shown in Photograph 5 onto the main circuit board fo...

Страница 6: ...pen Jumper Jumper Jumper Jumper Consumption in one 90 degree operation under battery power 15 1mA 15 1mA 253 7mA 25 7mA Battery charge 37mA h 37mA h 37mA h 37mA h Weight of BSR kit 0 38kg 0 38kg 0 38k...

Страница 7: ...e feedback gear aligns with the corre sponding slot in the plastic shaft Ensure the plug and socket connection between the main PCB and the DPS PCB is firmly made Step 3 Secure the DPS PCB with the se...

Страница 8: ...ction on the DPS circuit board selecting either 4 20mA or 0 10V control For reverse acting applications where the control input signal response reverses eg 4mA open and 20mA closed and fails to open p...

Страница 9: ...ory default Jumper fitted in position NC Fails closed on loss of input control signal Actuator fully Closed Actuator opening by input signal Actuator fully Open Actuator closing by input signal Actuat...

Страница 10: ...loss of control signal or see configuration options below stays put on loss of external power Configuration options 1 Closes on loss of control signal 2 Opens on loss of control signal 3 Stays put on...

Страница 11: ...ial execution on request 140 170 F07 F10 22 17 F12 x 22 star 300 350 F07 F10 22 17 F12 x 22 star WEATHERPROOF RATING The J3C electric actuators have an ingress protection rating of IP67 which gives th...

Отзывы: