background image

Specifications:   

J3

 

– 

H85

 

Materials of construction: 

The 

J3 

- H85 electric rotary actuator 

Model  

J3

 – H85 Electric Actuator

 

Visual indication of the 
actuator’s operating 

status is constantly 
shown by  a highly 

visible LED light. 
 

 

J3 

Voltage range - automatically sensed by actuator 

85-240 AC (1ph) or DC 

Operating time (0-90° no load)  

30 seconds  

Maximum break torque 

93.5 Nm  / 827 lb.ins 

Maximum operating torque (run/ reseat) 

85 Nm  / 752 lb.ins 

Duty rating 

75% 

IP Rating (IEC 60529) 

IP65 

Working angle    Standard (on request) 

90° (180° or 270° options) 

Mounting   ISO:5211 x DIN 3337 

F05 & F07 x 17 

Motor switches 

2 x SPDT micro switches 

End of travel confirmation (volt free) 

2 x SPDT micro switches 

Heater 

4 W 

Ambient temperature range 

-20° to +70°C   -4 to +158°F 

Electrical connecting plugs 

DIN 43650/ ISO4400 & C192 

Consumption:     

 

240V/1ph          At maximum torque 

0.09A 

240V DC          At maximum torque 

0.10A 

110V/ 1ph         At maximum torque 

0.22A 

110V DC          At maximum torque 

0.17A 

Weight 

3.0 kg 

Housing 

Anti-corrosive Polyamide 

Fasteners 

Stainless steel 

Gears 

Polyamide (speed reducing) & steel 

Shaft 

Stainless steel 

Output drive 

Zammac 

Position indicator 

Glass filled Polyamide 

Method of operation: 

On receipt of a continuous power signal within the voltage range shown above, the motor in the J3 

electric actuator runs and, via a flat gear system, rotates the output shaft. The motor is stopped by 

internal cams striking micro switches. On receipt of a reversing continuous signal, the motor turns in 
the opposite direction reversing the output drive. 
Note: The power signal needs to remain on at all times to activate the thermostatic anti-condensation 
heater. The volt free end of travel confirmation switches must NOT be used to cut the power. As they 

are set ahead of the final motor stop position, cutting the power on receipt of the end of travel signal 

will result in the J3 electric actuator stopping short of the full open or full closed position determined 
by the motor switch settings. 

Содержание J3-35

Страница 1: ...edecessor the J2 range to the next level With an all new rugged weath erproof and anti corrosive Polyamide housing the J3 valve actuator offers more user friendly features than the J2 and introduces a highly visible LED status light This visual indicator shows whether the actuator is operat ing correctly or has tripped out either by its electronic torque limiter or has been left in manual mode Sit...

Страница 2: ...At maximum torque 0 22A 110V DC At maximum torque 0 17A Weight 3 0 kg Housing Anti corrosive Polyamide Fasteners Stainless steel Gears Polyamide speed reducing steel Shaft Stainless steel Output drive Zammac Position indicator Glass filled Polyamide Method of operation On receipt of a continuous power signal within the voltage range shown above the motor in the J3 electric actuator runs and via a ...

Страница 3: ...he actuator in the failsafe position should the main power supply fail It can be configured normally open or normally closed Modulating Option Using the new self calibrating and self adjusting digital positioning system this kit converts the actuator to a modulating electric actuator using either a 4 20mA or 0 10VDC control signal An output signal is provided as standard Model J3 H85 Electric Actu...

Страница 4: ...against valve jams Anti condensation heater Manual override All connections via external DIN plugs no need to remove cover to connect Volt free end of travel confirmation switches IP65 weatherproof housing CE marked Traceable sequential serial num bering system Optional failsafe kit Battery Back up actuator fails to safe position on power failure Optional modulating kit with digital positioning sy...

Страница 5: ...6 hrs 36 hrs 36 hrs 36 hrs Not in production Not in production Nominal capacity 5 800mA 800mA 800mA 800mA Battery consumption per Movement W 0 1 0 18 0 23 Minimum recharge time after movement by battery 26 mins 26 mins 50 mins 65 mins Configuration The J3 BSR is factory supplied to fail closed on mains failure normally closed but can be configured to fail open normally open simply by removing a ju...