background image

The standard on-off 
version can have plug 
and play  failsafe or 
modulating kits retro-
fitted to convert the 
function. 
 

The modulating kit 
contains a self 
calibrating digital 
positioner. 

Dimensions:    

J3 

- H85 

Change of function retro-fit kits: 

Failsafe option 

This kit converts the electric actuator to a failsafe unit 

using a BSR  (Battery ‘Spring Return’) system that pro-

vides an alternative (battery) power supply to set the 

actuator in the failsafe position should the main power 
supply fail. 
It can be configured normally open, or normally closed. 

Modulating Option 

Using the new self calibrating and self adjusting digital 

positioning system, this kit converts the actuator to a 

modulating electric actuator using either a 4-20mA or 
0-10VDC control signal. 
An output signal is provided as standard. 

Model  

J3

 - H85 Electric Actuator

 

J3 

LED status light  

55mm  

 2.17” 

73mm 

 2.88” 

177mm  

 6.97” 

196mm   7.72” 

128mm   5.04” 

Mounting 

F05 

F07 

ISO: 5211 

50mm  70mm 

Drive

 

17mm 

 

Optional 

14mm 

Failsafe modulating option 

Install both kits 

J3

 Electric rotary actuator 

Содержание J3-35

Страница 1: ...edecessor the J2 range to the next level With an all new rugged weath erproof and anti corrosive Polyamide housing the J3 valve actuator offers more user friendly features than the J2 and introduces a highly visible LED status light This visual indicator shows whether the actuator is operat ing correctly or has tripped out either by its electronic torque limiter or has been left in manual mode Sit...

Страница 2: ...At maximum torque 0 22A 110V DC At maximum torque 0 17A Weight 3 0 kg Housing Anti corrosive Polyamide Fasteners Stainless steel Gears Polyamide speed reducing steel Shaft Stainless steel Output drive Zammac Position indicator Glass filled Polyamide Method of operation On receipt of a continuous power signal within the voltage range shown above the motor in the J3 electric actuator runs and via a ...

Страница 3: ...he actuator in the failsafe position should the main power supply fail It can be configured normally open or normally closed Modulating Option Using the new self calibrating and self adjusting digital positioning system this kit converts the actuator to a modulating electric actuator using either a 4 20mA or 0 10VDC control signal An output signal is provided as standard Model J3 H85 Electric Actu...

Страница 4: ...against valve jams Anti condensation heater Manual override All connections via external DIN plugs no need to remove cover to connect Volt free end of travel confirmation switches IP65 weatherproof housing CE marked Traceable sequential serial num bering system Optional failsafe kit Battery Back up actuator fails to safe position on power failure Optional modulating kit with digital positioning sy...

Страница 5: ...6 hrs 36 hrs 36 hrs 36 hrs Not in production Not in production Nominal capacity 5 800mA 800mA 800mA 800mA Battery consumption per Movement W 0 1 0 18 0 23 Minimum recharge time after movement by battery 26 mins 26 mins 50 mins 65 mins Configuration The J3 BSR is factory supplied to fail closed on mains failure normally closed but can be configured to fail open normally open simply by removing a ju...