REV 4-9-12
11
Inadequate wire size ran to machine.
Call electrician and install proper wire size for
electrical service versus length or run.
Wrong size breaker.
Install correct breaker (only if wire size is
adequate to handle breaker).
Inadequate wire size ran to machine.
Call electrician and install proper wire size for
electrical service versus length or run.
Motor brushes may be bad or too short.
Replace motor brushes.
Vac hose clogged?
Clean debris from vac hose.
Filter bags need cleaned or dirt chamber needs emptied?
Shake or clean filter bags or replace and empty
lower dirt chamber.
Vac hose is split?
Replace/repair vac hose.
Cleanout door gaskets torn or worn?
Replace gaskets.
Vac motor gaskets are worn or motor is not tight against.
Inspect/replace gaskets and assure motor is
tight against them.
Lower chamber cap plugs/mounting hole covers have
popped out?
Open lower chamber and inspect plugs, order
new if needed.
Cleanout door gaskets torn or worn?
Replace gaskets.
One of the vac motors is not working?
Check line motor fuse and replace. Replace
motor if necessary.
Coin mech might not be sending a pulse.
Replace coin mech if no switch closure/ pulse.
Timer may be bad - confirm voltage coming from timer when
active.
Replace timer if no voltage.
Water will not shut off.
Water solenoid is powered all the time. Remove power
source to test.
If removing power and water still runs, replace
solenoid.
Water will not come on.
Confirm there is voltage to solenoid.
If voltage is present, solenoid is bad - replace.
Lack of vacuum suction.
Machine will not start.
Unit keeps tripping
breaker.
Fuses for vac motors keep
blowing.