Programming:

The below timer pictured is the standard SSAC model that allows the end user to select the "coins to start" and 
the "time per coin" by settings series of dip switches. The number of "coins to start" dip switch is how many 
quarters are needed to make the machine come on. In the below example, the "one coin" dip is selected which 
makes the unit come on with one coin. The "time per coins" will then need to be set, but a good rule of thumb 
would be 4 minutes which requires dip switches 3.2 and .8 to be set to on.  This scenario means 1 quarter will 
provide 4 minutes of vacuum time.  The time per coin setting can be modified as desired by simply adding or 
subtracting time.  If the operator would later decide to increase the cost of the unit to "2" quarters, the 2 dip 
switch would need to be in the on position (all other off) and the time dip switches would need to have the 1.6 
and 0.4 dips selected.  This would allow 2 minutes of time for each quarter for a total of 4 minutes for two 
quarters.

Time in minutes/per coin dip switch settings:
0.1 = 6 seconds
0.2 = 12 seconds
0.4 = 24 seconds
0.8 = 48 seconds
1.6 = 96 seconds
3.2 = 192 seconds
6.4 = 384 seconds

Содержание 9730

Страница 1: ...ct Information Page 3 Specifications Page 4 Important Safety Instructions Page 5 6 Product Dimensions Page 6 8 Installation Page 8 9 Programming Page 10 Operating Instructions Page 10 11 Maintenance Troubleshooting Page 12 13 Parts List Page 14 Wiring Diagram ...

Страница 2: ...he lower exterior of the can Key number can be found on the tag that comes attached to the keys There may be more than one key number depending on unit Please keep this information with your records MODEL ____________________________ SERIAL ____________________________ KEY NUMBER S _____________________ DATE PURCHASED ___________________ DISTRIBUTOR _______________________ J E Adams Industries 102...

Страница 3: ...cuum side Motors 2 120VAC vacuum motor Fuses 2 10 amp inline fuses Water side Solenoid 120V 60hz 05amps NOTES Solenoid to be used with city water pressure only Not intended for human consumption NOTE Two separate electrical services are required for this unit This combo machine has two functions each having it s own coin mechanism that starts the function NOTE UNIT INTENDED FOR COMMERCIAL USE ONLY...

Страница 4: ... not pick up anything that is burning or smoking such as cigarettes matches or hot ashes Do not use without dust bag and or filters in place SAVE THESE INSTRUCTIONS Installation Instructions Determine location to mount unit DANGER THIS EQUIPMENT INCORPORATES PARTS SUCH AS SWITCHES MOTORS OR THE LIKE THAT TEND TO PRODUCE ARCS OR SPARKS THAT CAN CAUSE AN EXPLOSION WHEN LOCATED IN GASOLINE DISPENSING...

Страница 5: ...REV 4 9 12 5 Product Dimensions ...

Страница 6: ...holes into concrete surface and install 3 8 studs 4 NOTE when mounting provide clearance so cleanout doors can open Bring electrical in underneath can and route up front channel to terminal strip Water service can come up back channel ...

Страница 7: ...REV 4 9 12 7 Bring BOTH services up through this channel and hook each into a terminal strip Terminal strips Water service can come up back channel ...

Страница 8: ...it has been installed use 5871B8 cap plugs supplied with unit to seal holes in canister bottom located in lower cleanout door Extra cap plugs are included with the unit in case plug becomes damaged during shipping removal To attach hose thread into metal hole counter clockwise Edge of hose will need to start here To insert 5871B8 cap plugs into bottom holes pinch cap plug into place using index fi...

Страница 9: ... requires dip switches 3 2 and 8 to be set to on This scenario means 1 quarter will provide 4 minutes of vacuum time The time per coin setting can be modified as desired by simply adding or subtracting time If the operator would later decide to increase the cost of the unit to 2 quarters the 2 dip switch would need to be in the on position all other off and the time dip switches would need to have...

Страница 10: ...onths water must be shut off to unit and water line must be purged to prevent line breakage Clean canister with a stainless steel cleaner as needed Decals can be cleaned with mild soap and water Check motor brushes every month for excessive wear Motor brushes should be changed immediately if they are shorter than Please disconnect power before doing this DISCONNECT POWER BEFORE SERVICING OR TROUBL...

Страница 11: ...worn or motor is not tight against Inspect replace gaskets and assure motor is tight against them Lower chamber cap plugs mounting hole covers have popped out Open lower chamber and inspect plugs order new if needed Cleanout door gaskets torn or worn Replace gaskets One of the vac motors is not working Check line motor fuse and replace Replace motor if necessary Coin mech might not be sending a pu...

Страница 12: ...REV 4 9 12 12 ...

Страница 13: ...REV 4 9 12 13 ...

Страница 14: ...REV 4 9 12 14 ...

Отзывы: