OPERATION
LOAD HOOK
Check the hook opening “a” and the height “h” of the load hook of
JDN Air Hoists that are in use at least once a year (see Check
dimensions, page 58ff).
Load hooks should not
be loaded at the tip,
be adjusted,
be annealed.
If the load hook is bent, the JDN Air Hoist must be sent
for inspection.
The permitted load hook temperature range is -40°C
to +150°C.
ATTACHING THE LOAD
DANGER!
Only use attaching cables or attaching chains which
are suitable for the load. Attaching must not be
attempted by winding with the lifting chain around
the load.
In Germany, the trade association regulations
“Operation of load
carrying devices used with lifting equipment” (BGR 258) must be
adhered to.
In other countries, the relevant local regulations
must be observed.
Attaching aids must be attached at the lowest point of the
hook. Never load the tip of the hook.
Ensure that the hook safety catch is closed.
Secure load attachment