All sensors must be configured with the network ID in
order to communicate with the Monitor. The network ID
can be found on the back of the Monitor or can be extract
ed thru operation software. The sensor configuration can
be done with a Visum Monitor. Check how it can be done
in this manual.
The following steps must be done:
2.
Wake up the sensor by shaking it.
3.
Place the magnet on the address indicator
(make circular movement to easily turn on the
internal switch).
4.
Wait for the confirmation beep or message.
5.
Fill the address indicator with the number of
the implement and row.
Network ID
1.
Find the address indicator
on the rubber cover.
ATTENTION:
Never configure two sensors at the same time,
even with two different devices, because the
connections may cross each other.
TIP:
1.
In order to change the address of any sensor,
just follow the steps again, before doing the
sensor
“addressing procedure”.
2.
When installing the sensors on your machine
initially, we recommend you “address” the
sensors to the monitor on your workbench
first before installing the sensors on the
toolbar row units.